Combined Gradation Report
Report Name: HMA Aggregates (Size 3/4"): Type A HMA - Continuous Mixing Plant - Sieve Analysis With RAP
Report ID: Combined Gradation-2024-06-12
Specification: 2023 Caltrans Standard Specification - Type A HMA 3/4 inch
|
Subsample Material DIME Sample ID Test Method Percentage Other |
1 Aggregate 2024-05-23-54 AASHTO T27-14 Percentage 75 % Total WT 5382 g Fine Agg WT 433 g | 2 Aggregate 2024-05-23-53 AASHTO T30-19 Percentage 25 % Total WT 2394.1 g Correction Factor: Yes |
Combined Gradation 100 % |
Target Value |
Specification Limits (Target Value ± Tolerance) | |||||
|
Sieve Size |
WT RET | % PASS | % USED | WT RET | CF | % PASS | % USED |
% PASS
|
% PASS |
% PASS |
|
2" |
0.0 | 100 | 75.0 | 0.0 | 0 | 100 | 25.0 | 100 | 100 | - |
|
1½" |
0.0 | 100 | 75.0 | 0.0 | 0 | 100 | 25.0 | 100 | 100 | - |
|
1" |
0.0 | 100 | 75.0 | 0.0 | 0 | 100 | 25.0 | 100 | 100 | 100 - 100 |
|
¾" |
452.1 | 92 | 68.7 | 26.6 | 0.2 | 99 | 24.8 | 93 | 91 | 86 - 96 |
|
½" |
1,590.2 | 70 | 52.8 | 104.8 | -5.1 | 91 | 22.6 | 75 | 77 | 71 - 83 |
|
⅜" |
2,089.7 | 61 | 45.9 | 264.7 | -5.1 | 84 | 21.0 | 67 | 70 | - |
|
No. 4 |
3,622.2 | 33 | 24.5 | 684.9 | -6.5 | 65 | 16.2 | 41 | 44 | 39 - 49 |
|
No. 8 |
168.4 | 20 | 15.0 | 1,009.2 | -3 | 55 | 13.7 | 29 | 29 | 24 - 34 |
|
No. 16 |
246.1 | 14 | 10.6 | 1,324.1 | -2.4 | 42 | 10.6 | 21 | 21 | - |
|
No. 30 |
296.3 | 10 | 7.7 | 1,575.5 | -2.4 | 32 | 7.9 | 16 | 15 | 11 - 19 |
|
No. 50 |
335.6 | 7 | 5.5 | 1,799.8 | -2.7 | 22 | 5.5 | 11 | 10 | - |
|
No. 100 |
366.3 | 5 | 3.8 | 1,994.9 | -2.5 | 14 | 3.5 | 7 | 6 | - |
|
No. 200 |
388.2 | 3.4 | 2.5 | 2,146.8 | -2.1 | 8.2 | 2.1 | 4.6 | 3.3 | 1.3 - 5.3 |
|
General comments |
CF-R94 Aggregates |
CF-R93 RAP | ||||||||
Gradation By: Derek Carrington
Report Comment: CF-R94 Sample Tested at the Olancha Lab, Data entered at the Main Lab
Published By: Derek Carrington
Published Date: 2024-05-23
Published Comment: CF-R95 Sample Tested at the Olancha Lab, Data entered at the Main Lab
Report Comment: CF-R94 Sample Tested at the Olancha Lab, Data entered at the Main Lab
Published By: Derek Carrington
Published Date: 2024-05-23
Published Comment: CF-R95 Sample Tested at the Olancha Lab, Data entered at the Main Lab