Combined Gradation Report

Report Name: HMA Aggregates (Size 3/4"): Type A HMA - Continuous Mixing Plant - Sieve Analysis With RAP
Report ID: Combined Gradation-2024-09-72
Specification: 2023 Caltrans Standard Specification - Type A HMA 3/4 inch

Subsample

Material

DIME Sample ID

Test Method

Percentage

Other

1

Aggregate

2024-09-26-8

AASHTO T27-14

Percentage 85 %

2

Aggregate

2024-09-26-8

AASHTO T30-19

Percentage 15 %

Total WT 1498 g

Correction Factor: Yes

Combined Gradation

100 %

Target Value

Specification Limits

(Target Value ± Tolerance)

Sieve Size

% PASS% USEDWT RETCF% PASS% USED
% PASS

% PASS

% PASS

2"

10085.00.0010015.0

100

100 -

1½"

10085.00.0010015.0

100

100 -

1"

10085.00.0010015.0

100

100 100 - 100

¾"

9580.40.0010015.0

95

96 91 - 100

½"

7765.60.0010015.0

81

83 77 - 89

⅜"

7059.80.0-0.110015.0

75

74 -

No. 4

5344.7486.45.27310.9

56

58 53 - 63

No. 8

3630.9820.42.3487.1

38

39 34 - 44

No. 16

2521.01,019.5-1.1314.6

26

27 -

No. 30

1814.91,148.0-5.6182.7

18

18 14 - 22

No. 50

129.91,250.5-4.2121.8

12

12 -

No. 100

75.81,322.0-2.2101.4

7

7 -

No. 200

3.22.71,372.4-1.37.11.1

3.8

4.1 2.1 - 6.1

General comments

CF-18 Agg

CF-18 RAP

Gradation By: Derek Carrington
Report Comment: CF-18
Published By: Derek Carrington
Published Date: 2024-09-30
Published Comment: CF-18