Combined Gradation Report

Report Name: HMA Aggregates (Size 3/4"): Type A HMA - Continuous Mixing Plant - Sieve Analysis With RAP
Report ID: Combined Gradation-2024-08-22
Specification: 2023 Caltrans Standard Specification - Type A HMA 3/4 inch

Subsample

Material

DIME Sample ID

Test Method

Percentage

Other

1

Aggregate

2024-08-26-5

AASHTO T27-14

Percentage 75 %

2

Aggregate

2024-08-26-6

AASHTO T30-19

Percentage 25 %

Total WT 1674.8 g

Correction Factor: Yes

Combined Gradation

100 %

Target Value

Specification Limits

(Target Value ± Tolerance)

Sieve Size

% PASS% USEDWT RETCF% PASS% USED
% PASS

% PASS

% PASS

2"

10075.00.0010025.0

100

100 -

1½"

10075.00.0010025.0

100

100 -

1"

10075.00.0010025.0

100

100 100 - 100

¾"

9571.20.0010025.0

96

98 93 - 100

½"

7254.20.0010025.0

79

81 75 - 87

⅜"

6347.30.0010025.0

72

73 -

No. 4

4836.2376.8-3.77418.5

55

52 47 - 57

No. 8

3929.2754.0-2.75213.1

42

40 35 - 45

No. 16

2922.0984.9-2399.8

32

30 -

No. 30

1914.01,152.7-2297.3

21

22 18 - 26

No. 50

96.71,299.6-1.7215.2

12

14 -

No. 100

42.61,424.2-0.9143.5

6

8 -

No. 200

2.51.91,502.3-0.79.62.4

4.3

5.6 3.6 - 7.6

General comments

CF-3 Aggs

CF-3 RAP

Gradation By: Derek Carrington
Report Comment: CF-3
Published By: Derek Carrington
Published Date: 2024-08-27
Published Comment: CF-3