Combined Gradation Report

Report Name: HMA Aggregates (Size 3/4"): Type A HMA - Continuous Mixing Plant - Sieve Analysis With RAP
Report ID: Combined Gradation-2024-07-39
Specification: 2023 Caltrans Standard Specification - Type A HMA 3/4 inch

Subsample

Material

DIME Sample ID

Test Method

Percentage

Other

1

Aggregate

2024-07-16-56

AASHTO T27-14

Percentage 75 %

2

Aggregate

2024-07-16-55

AASHTO T30-19

Percentage 25 %

Total WT 2016.2 g

Correction Factor: Yes

Combined Gradation

100 %

Target Value

Specification Limits

(Target Value ± Tolerance)

Sieve Size

% PASS% USEDWT RETCF% PASS% USED
% PASS

% PASS

% PASS

2"

10075.00.0010025.0

100

100 -

1½"

10075.00.0010025.0

100

100 -

1"

10075.00.0010025.0

100

100 100 - 100

¾"

9470.224.80.29924.7

95

91 86 - 96

½"

7254.2210.4-5.18421.1

75

77 71 - 83

⅜"

6750.5353.2-5.17719.3

70

70 -

No. 4

3727.4717.1-6.55814.5

42

44 39 - 49

No. 8

2115.5979.3-34812.1

28

29 24 - 34

No. 16

1511.01,207.4-2.4389.4

20

21 -

No. 30

118.01,390.1-2.4297.2

15

15 11 - 19

No. 50

85.71,555.5-2.7205.0

11

10 -

No. 100

53.81,701.6-2.5133.3

7

6 -

No. 200

3.42.61,812.2-2.18.02.0

4.6

3.3 1.3 - 5.3

General comments

CF-R183

CF-R182 RAP

Gradation By: Derek Carrington
Report Comment: CF-R183
Published By: Derek Carrington
Published Date: 2024-07-22
Published Comment: CF-R183