Combined Gradation Report

Report Name: HMA Aggregates (Size 3/4"): Type A HMA - Continuous Mixing Plant - Sieve Analysis With RAP
Report ID: Combined Gradation-2024-07-26
Specification: 2023 Caltrans Standard Specification - Type A HMA 3/4 inch

Subsample

Material

DIME Sample ID

Test Method

Percentage

Other

1

Aggregate

2024-07-08-13

AASHTO T27-14

Percentage 75 %

2

Aggregate

2024-07-08-12

AASHTO T30-19

Percentage 25 %

Total WT 2567.9 g

Correction Factor: Yes

Combined Gradation

100 %

Target Value

Specification Limits

(Target Value ± Tolerance)

Sieve Size

% PASS% USEDWT RETCF% PASS% USED
% PASS

% PASS

% PASS

2"

10075.00.0010025.0

100

100 -

1½"

10075.00.0010025.0

100

100 -

1"

10075.00.0010025.0

100

100 100 - 100

¾"

9369.432.60.29924.7

94

91 86 - 96

½"

7254.2375.5-5.18020.1

74

77 71 - 83

⅜"

6045.3550.3-5.17318.4

64

70 -

No. 4

3425.2966.2-6.55614.0

39

44 39 - 49

No. 8

2116.11,296.1-34711.6

28

29 24 - 34

No. 16

1611.81,592.4-2.4368.9

21

21 -

No. 30

118.61,827.0-2.4266.6

15

15 11 - 19

No. 50

85.92,034.1-2.7184.5

10

10 -

No. 100

53.72,212.2-2.5112.8

7

6 -

No. 200

3.12.32,346.3-2.16.51.6

3.9

3.3 1.3 - 5.3

General comments

CF-R170

CF-R169 RAP

Gradation By: Derek Carrington
Report Comment: CF-R170
Published By: Derek Carrington
Published Date: 2024-07-19
Published Comment: CF-R170