Print Report | Back to Test Summary

Testing Report for 2019-06-21-1-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080Q9104
EFIS: 0800020580
Project ID: 213747
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10-R23.8
Work Description: RETROFIT BRIDGE PIER WALLS, FOOTINGS AND POLYESTER CONCRETE OVERLAY.
Location Description: SAN BERNARDINO COUNTY IN COLTON AT THE SANTA ANA RIVER BRIDGES
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Roberto Castro
Structure Rep.: Ching Chuang

Sample Information

DIME Sample ID: 2019-06-21-1
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 6/21/2019
Date that the sample was received by the laboratory/organization performing the testing: 6/24/2019
The quantity of what the sample constitutes: 6 bars, 1 coupler, 6 hex nuts
A brief description of the sample: ATB A722 plus couplers and hardware
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Form Engineering

Material Information

Production or Authorization Testing: Authorization Testing
Threaded Bar Specification: ASTM A722
Threaded Bar Grade: 150
Threaded Bar Type:
Rebar Size:
Nut Specification for Threaded Bar: Unknown
System Manufacturer: Unknown
Epoxy Coating Color: NA
Threaded Bar Application:
Coating Standards: Uncoated
Bar Heat Number(s): 1000796073, 1000891061, 100891062
Nut Heat Number(s): 75072337 (64D1D)
Bar Lot Number: Unknown
Nut Lot Number: Unknown
Coupler Heat Number(s): C158181 (64U8D)
Coupler Grade: Unknown

Test Information

DIME Test ID: 2019-06-21-1-8
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Date Tested: 7/3/2019
Verified Date: 7/3/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Bar 3 Heat # 100891062 with Coupler Test Only
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Threaded Bar Samples: 1
Sample Size Mfg Lot Area (sqin) Tensile Strength (psi) Stress at Offset (psi) Total Elongation (%) Reduction of area (%) Comments Tested By
8 ASTM A722 Type II Deformed Bar 2 1/2 : 65mm NA 5.16 158476.82 153.99 -100 100 Bar 3 Heat # 100891062 with Coupler Test Only bewing
Temperature: 72 f
UTM: 2000kip