Sample Record for 2017-06-09-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 210097 DEA: 100L9704 EFIS: 1012000053
QA Service Level: 1
DIST-CO-RTE-PM: 10-TUO-120-R19.5/R20.0
Work Description: REPLACE DECK AND RETROFIT BRIDGE.
Location Description: IN TUOLUMNE COUNTY ON STATE ROUTE 120 FROM 7.6 MILES EAST OF YOSEMITEJUNCTION TO 4.8 MILES WEST OF THE TOWN OF MOCCASIN AT TUOLUMNE RIVER/DON PEDRO RESERVOIR (JAMES E.
Contractor Name: Golden State Bridge
Contractor Address: 3701 Mallard Drive, Benicia, CA 94510
Resident Engineer: Corey Casey Structure Rep.: Ehab Wahed
Sample Information
DIME Sample ID: 2017-06-09-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Acceptance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 06/09/2017
Date that the sample was received by the laboratory/organization performing the testing: 06/14/2017
The quantity of what the sample constitutes: 28
A brief description of the sample: A449 HDG Tie Rod
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Portland Bolt
Material Information
Rocap Number(s): N/A
Heat Number(s): 75062939
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: A449
Bolt Length(s): 74-1/8, 72-5/8, 70-1/4, 66-5/8, 64-5/8, 63-1/
Nut Specification: N/A
Washer Specification: N/A
Finish: HDG
Diameter/Size: 1.125
Bolt Mfg. Lot Number: 12478
Rocap Test Requirement(s): No
Lubricant Requirements(s):
Test Results
Test 1 of 4
DIME Test ID: 2017-06-09-1-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 06/15/2017
Date Tested: 06/14/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A449 w/ Clevis
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments | 1A | A449 w/ Clevis | 0.763 | 86364 | 384 | 113190 | 98338 | 75032 | A449 w/ Clevis |
| |
UTM
|
400KIP
|
Temperature
|
71
|
Test 2 of 4
DIME Test ID: 2017-06-09-1-2
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 06/15/2017
Date Tested: 06/14/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A449 w/ Clevis
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments | 1B | A449 w/ Clevis | 0.763 | 87043 | 387 | 114080 | 100787 | 76900 | A449 w/ Clevis |
| |
UTM
|
400KIP
|
Temperature
|
71
|
Test 3 of 4
DIME Test ID: 2017-06-09-1-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 06/15/2017
Date Tested: 06/14/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
75062939
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449
|
Size
|
1.125 in
|
Bolt Length
|
74.125 in
|
Gage Type
|
Pass
|
Test 4 of 4
DIME Test ID: 2017-06-09-1-4
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/15/2017
Date Tested: 06/14/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
75062939
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449
|
Size
|
1.125 in
|
Bolt Length
|
74.125 in
|
Measurement Average
|
6.95 mils
|