Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-06-09-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210097
DEA: 100L9704
EFIS: 1012000053
DIST-CO-RTE-PM10-TUO-120-R19.5/R20.0
Award Date02/22/2016
Closeout Date10/09/2018
Work DescriptionREPLACE DECK AND RETROFIT BRIDGE.
Location DescriptionIN TUOLUMNE COUNTY ON STATE ROUTE 120 FROM 7.6 MILES EAST OF YOSEMITEJUNCTION TO 4.8 MILES WEST OF THE TOWN OF MOCCASIN AT TUOLUMNE RIVER/DON PEDRO RESERVOIR (JAMES E.
QA Service Level1 (Verified on 12/19/2014)

Sample Information

Sample Taken Date06/09/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/14/2017
Sample typeAcceptance A brief description of the sampleA449 HDG Tie Rod
The quantity of what the sample constitutes28 From where was the sample collectedManufacturer
First name of sampler or witnessed byScott Last name of sampler or witnessed byLeavitt
Title of samplerQA Inspector Telephone number of sampler5105900119
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namePortland Bolt Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormS28-170-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)N/A
Heat Number(s)75062939 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationA449
Bolt Length(s)74-1/8, 72-5/8, 70-1/4, 66-5/8, 64-5/8, 63-1/ Nut SpecificationN/A
Washer SpecificationN/A FinishHDG
Diameter/Size1.125 Bolt Mfg. Lot Number12478
Rocap Test Requirement(s)No Lubricant Requirements(s)

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-06-09-1-1ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)Arnold, CT HQ - Sacramento Structural Materials Testing Laboratory06/14/2017Arnold
Yes
06/22/2017A449 w/ Clevis
2017-06-09-1-2ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)Arnold, CT HQ - Sacramento Structural Materials Testing Laboratory06/14/2017Arnold
Yes
06/22/2017A449 w/ Clevis
2017-06-09-1-3ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Arnold Viken, CT HQ - Sacramento Structural Materials Testing Laboratory06/14/2017Arnold Viken
Yes
06/22/2017
2017-06-09-1-4ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Arnold Viken, CT HQ - Sacramento Structural Materials Testing Laboratory06/14/2017Arnold Viken
Yes
06/22/2017

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-06-09-1-1 ASTM F606-14 (Verified)
DIME Test ID: 2017-06-09-1-2 ASTM F606-14 (Verified)
DIME Test ID: 2017-06-09-1-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-09-1-4 ASTM B499-14 (Verified)