Print Report | Back to Test Summary

Testing Report for 2021-04-01-7-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 030F2864
EFIS: 0320000123
Project ID: 214702
QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-99-7.92 / 8.4
Work Description: Remove and replace Consumnes River and Consumnes River Overflow bridge
Location Description: Sacramento County
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Masoud Saed
Structure Rep.: Chau Ha

Sample Information

DIME Sample ID: 2021-04-01-7
TL Number from the TL Form:
Sample Submitted By Organization: CT METS QASI - Los Angeles Design Build Field Laboratory
Sample Organization Contact: (619) 204-7248
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 4/1/2021
Date that the sample was received by the laboratory/organization performing the testing: 4/5/2021
The quantity of what the sample constitutes: 560
A brief description of the sample: #8 welded hoops (4'-6" dia)
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CMC Rebar Etiwanda

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 4104470
Hoop Manufacturer Lot Number(s): Lots 14 - 17
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #8
Diameter of Hoop: 4'-6"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: CMC Steel Arizona
Welding Company: CMC Rebar (Etiwanda)
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Information

DIME Test ID: 2021-04-01-7-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Date Tested: 4/6/2021
Verified Date: 4/6/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Ok Necking
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Peak Load (lbf) Peak Stress (psi) Comments Tested By
2 17 8/25mm 0.79 72888.10 92263 Ok Necking bewing
UTM: 400kip
Temperature: 72 f