Print Report | Back to Sample Detail

Sample Record for 2023-11-08-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214487 DEA: 120Q9304 EFIS: 1217000128 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-5,133,241-122,241-var
Work Description: 12-0Q930, SHOPP RESERVATION BRIDGE PROJECT - BRIDGE UPGRADE, WINGWALL, SUBSTRUCTURE, DECK, SPALL, JOINT SEAL, CONC.
Location Description: ORANGE COUNTY AT VARIOUS LOCATIONS
Contractor Name: PETERSON CHASE GENERAL ENGINEERING CONSTRUCTION INC
Contractor Address: 1792 KAISER AVENUE, IRVINE CA 92614
Resident Engineer: Mario Leon Structure Rep.: Josefino Valencia

Sample Information

DIME Sample ID: 2023-11-08-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 11/08/2023
Date that the sample was received by the laboratory/organization performing the testing: 11/13/2023
The quantity of what the sample constitutes: 400 Qty. A325 fastener assemblies
A brief description of the sample: A325 Fastener Assemblies
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cordova Bolt Inc. Buena Park, CA.

Material Information

Rocap Number(s):
Heat Number(s): 1000118723, 20833010, 42325080
Nut Mfg. Lot Number(s): E589J1
Washer Mfg. Lot Number(s): 0823-822
Bolt Specification: ASTM A325
Bolt Length(s): 3
Nut Specification: ASTM A563
Washer Specification: ASTM F436
Finish: Plain
Diameter/Size: 3/4" -10
Bolt Mfg. Lot Number: W000032472
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 13

DIME Test ID: 2023-11-08-2-1
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 11/22/2023
Date Tested: 11/15/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1A63792Proof Load
UTM 450kip
Temperature 72 f

Test 2 of 13

DIME Test ID: 2023-11-08-2-2
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 11/22/2023
Date Tested: 11/15/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1B64270Proof Load
UTM 450kip
Temperature 72 f

Test 3 of 13

DIME Test ID: 2023-11-08-2-3
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 11/22/2023
Date Tested: 11/15/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1AW0000324720.750047614211.810.00Wedge Tensileaauvinen
UTM 450kip
Temperature no data

Test 4 of 13

DIME Test ID: 2023-11-08-2-4
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 11/22/2023
Date Tested: 11/15/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1BW0000324720.750047218210.0410.00Wedge Tensileaauvinen
UTM 450kip
Temperature no data

Test 5 of 13

DIME Test ID: 2023-11-08-2-5
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 11/22/2023
Date Tested: 11/20/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000032472
Finish Coating Plain
Product Markings A325 N USA
Size .75 in
Bolt Length 3 in
Gage Type Pass

Test 6 of 13

DIME Test ID: 2023-11-08-2-6
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 11/22/2023
Date Tested: 11/20/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000032472
Finish Coating Plain
Product Markings A325 N USA
Size .75 in
Bolt Length 3 in
Gage Type Pass

Test 7 of 13

DIME Test ID: 2023-11-08-2-7
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 11/22/2023
Date Tested: 11/20/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000032472
Finish Coating Plain
Product Markings A325 N USA
Size .75 in
Bolt Length 3 in
Gage Type Pass

Test 8 of 13

DIME Test ID: 2023-11-08-2-8
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 11/22/2023
Date Tested: 11/20/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E589J1
Finish Coating Plain
Product Markings DH LE USA
Size 0.75 in
Gage Type Pass

Test 9 of 13

DIME Test ID: 2023-11-08-2-9
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 11/22/2023
Date Tested: 11/20/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E589J1
Finish Coating Plain
Product Markings DH LE USA
Size 0.75 in
Gage Type Pass

Test 10 of 13

DIME Test ID: 2023-11-08-2-10
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 11/22/2023
Date Tested: 11/20/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E589J1
Finish Coating Plain
Product Markings DH LE USA
Size 0.75 in
Gage Type Pass

Test 11 of 13

DIME Test ID: 2023-11-08-2-11
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 11/22/2023
Date Tested: 11/20/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 0823-822
Finish Coating Plain
Product Markings TSI F436
Size 0.75 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 41
Spacing Ok

Test 12 of 13

DIME Test ID: 2023-11-08-2-12
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 11/22/2023
Date Tested: 11/20/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 0823-822
Finish Coating Plain
Product Markings TSI F436
Size 0.75 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 42.15
Spacing Ok

Test 13 of 13

DIME Test ID: 2023-11-08-2-13
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 11/22/2023
Date Tested: 11/20/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 0823-822
Finish Coating Plain
Product Markings TSI F436
Size 0.75 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 41.4
Spacing Ok