Print Report | Back to Sample Detail

Sample Record for 2023-04-03-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993169 DEA: 050A0904 EFIS: 0513000028 QA Service Level: 1
DIST-CO-RTE-PM: 05-MON-156-R1.4/R2.0
Work Description: WIDEN REINFORCED STRUCTURAL CONCRETE BRIDGE & REPLACE BRIDGE RAILING.
Location Description: MONTEREY COUNTY IN AND NEAR CASTROVILLE FROM 0.3 MILE EAST OF ROUTE 156/183 SEPARATION TO 0.2 MILE EAST OF CASTROVILLE BOULEVARD
Contractor Name: Granite Rock (Bryan Jones)
Contractor Address: 5225 Hellyer Ave, Ste 220, San Jose, CA 95138
Resident Engineer: David Hopper Structure Rep.: Dean Russu

Sample Information

DIME Sample ID: 2023-04-03-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 04/03/2023
Date that the sample was received by the laboratory/organization performing the testing:
The quantity of what the sample constitutes: 84
A brief description of the sample: #5 HRC 120 T-Heads
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Headed Reinforcement Corporation (HRC)

Material Information

Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 1201038422
Head Manufacturer Lot Number(s): 100021624144
Rebar Size: #5
Headed Bar Model Name: HRC 120
Size of Head: Full Size - 9x
Head Connection Type: Friction Weld
Head Shape: Square
Rebar Manufacturer: Nucor
Head Manufacturer: Nucor Utah
Head Fabricator: Nucor
Material Standard Code: ASTM A706
Headed Bar Unique ID: 9FW-17-03

Test Results

Test 1 of 4

DIME Test ID: 2023-04-03-1-1
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 04/24/2023
Date Tested: 04/05/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Head Popped Off
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
10.312867792505Head Popped Offbewing
Temperature 72 f
UTM 400kip

Test 2 of 4

DIME Test ID: 2023-04-03-1-2
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 04/24/2023
Date Tested: 04/05/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
10.312884393043Ok Neckingbewing
Temperature 72 f
UTM 400kip

Test 3 of 4

DIME Test ID: 2023-04-03-1-3
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 04/24/2023
Date Tested: 04/05/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Head Popped Off
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
10.312732688149Head Popped Offbewing
Temperature 72 f
UTM 400kip

Test 4 of 4

DIME Test ID: 2023-04-03-1-4
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 04/24/2023
Date Tested: 04/05/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
10.312876792796Ok Neckingbewing
Temperature 72 f
UTM 400kip