Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214402 DEA: 010E7704 EFIS: 0115000009
QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-101-R17.9/87.8
Work Description: STRENGTHEN 2 BRIDGES.
Location Description: HUMBOLDT COUNTY AT SOUTH FORK EEL RIVER AND SEPARATION AND AT ARCATA OVERHEAD
Contractor Name: Freyssinet Inc
Contractor Address: 44880 Falcon Place, Suite 100, Sterling, VA 20166
Resident Engineer: Joaquin Rodriguez Structure Rep.: Ryan Duran
DIME Sample ID: 2022-07-01-26
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/01/2022
Date that the sample was received by the laboratory/organization performing the testing: 07/05/2022
The quantity of what the sample constitutes: 61
A brief description of the sample: A325 Bolts
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Birmingham Fastener
Rocap Number(s):
Heat Number(s): 1000213628
Nut Mfg. Lot Number(s): 465436B
Washer Mfg. Lot Number(s): E2081
Bolt Specification: A325
Bolt Length(s): 4.75"
Nut Specification: A563
Washer Specification: F436
Finish: HDG
Diameter/Size: 1"
Bolt Mfg. Lot Number: 466739A
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2022-07-01-26-1
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 1A | 466739A | 1.0000 | 87370 | 388.64 | 10.00 | A325 Wedge Tensile | spaine |
| |
UTM
|
450kip
|
Temperature
|
no data
|
DIME Test ID: 2022-07-01-26-2
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 1A | | | 94151 | | Nut Proof Load | |
| |
UTM
|
450kip
|
Temperature
|
72 f
|
DIME Test ID: 2022-07-01-26-3
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
466739A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1 in
|
Bolt Length
|
4.75 in
|
Gage Type
|
Pass
|
DIME Test ID: 2022-07-01-26-4
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
466739A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1 in
|
Bolt Length
|
4.75 in
|
Gage Type
|
Pass
|
DIME Test ID: 2022-07-01-26-5
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
466739A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1 in
|
Bolt Length
|
4.75 in
|
Gage Type
|
Pass
|
DIME Test ID: 2022-07-01-26-6
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
465436B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1 in
|
Gage Type
|
Pass
|
DIME Test ID: 2022-07-01-26-7
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
465436B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1 in
|
Gage Type
|
Pass
|
DIME Test ID: 2022-07-01-26-8
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
465436B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1 in
|
Gage Type
|
Pass
|
DIME Test ID: 2022-07-01-26-9
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
466739A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1 in
|
Bolt Length
|
4.75 in
|
Measurement Average
|
3.88 mils
|
DIME Test ID: 2022-07-01-26-10
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
466739A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1 in
|
Bolt Length
|
4.75 in
|
Measurement Average
|
4.84 mils
|
DIME Test ID: 2022-07-01-26-11
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
466739A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1 in
|
Bolt Length
|
4.75 in
|
Measurement Average
|
2.87 mils
|
DIME Test ID: 2022-07-01-26-12
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
465436B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
4.55 mils
|
DIME Test ID: 2022-07-01-26-13
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
465436B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.46 mils
|
DIME Test ID: 2022-07-01-26-14
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
465436B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.33 mils
|
DIME Test ID: 2022-07-01-26-15
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E2081
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 P
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.24 mils
|
DIME Test ID: 2022-07-01-26-16
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E2081
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 P
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.61 mils
|
DIME Test ID: 2022-07-01-26-17
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E2081
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 P
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.61 mils
|
DIME Test ID: 2022-07-01-26-18
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E2081
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 P
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
39.6
|
Spacing
|
Ok
|
DIME Test ID: 2022-07-01-26-19
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/11/2022
Date Tested: 07/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E2081
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 P
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
39.7
|
Spacing
|
Ok
|