Sample Record for 2019-10-16-6
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-710-6.0-9.4
Work Description: Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location Description: Port of Long Beach (District 7)
Contractor Name: Shimmick/FCC/Impregilo (SFI) JV
Contractor Address: 11 Golden Shore, Suite 330, Long Beach, CA 90802
Resident Engineer: Structure Rep.:
Sample Information
DIME Sample ID: 2019-10-16-6
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Acceptance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 10/16/2019
Date that the sample was received by the laboratory/organization performing the testing: 10/21/2019
The quantity of what the sample constitutes: 6
A brief description of the sample: A490 Bolts
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: LeJeune
Material Information
Rocap Number(s):
Heat Number(s): 75073905 6214661005 140647 75067668 10508080 6214506106 262342 75070176 6214552009 277861
Nut Mfg. Lot Number(s): 30581-6214661005 28846-6214661005 27185-6214506106 27807-6214552009
Washer Mfg. Lot Number(s): 0115-716 D3644 114 D4851
Bolt Specification: A490
Bolt Length(s): 6" 7" 10"
Nut Specification: A563 DH
Washer Specification: F436
Finish: Geomet
Diameter/Size: 1.25"
Bolt Mfg. Lot Number: 050919-4FM 041719-1CM 051519-7EM 27128-105
Rocap Test Requirement(s):
Lubricant Requirements(s):
Test Results
Test 1 of 30
DIME Test ID: 2019-10-16-6-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 10/29/2019
Date Tested: 10/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test: A490 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 1A | 050919-4FM | 1.2500 | 158360 | 704.42 | 6.00 | A490 Wedge Tensile | spaine |
| |
UTM
|
450kip
|
Temperature
|
no data
|
Test 2 of 30
DIME Test ID: 2019-10-16-6-2
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 10/29/2019
Date Tested: 10/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test: A490 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 2A | 041719-1CM | 1.2500 | 150386 | 668.95 | 6.00 | A490 Wedge Tensile | spaine |
| |
UTM
|
450kip
|
Temperature
|
no data
|
Test 3 of 30
DIME Test ID: 2019-10-16-6-3
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 10/29/2019
Date Tested: 10/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test: A490 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 3A | 051519-7EM | 1.2500 | 153226 | 681.58 | 6.00 | A490 Wedge Tensile | spaine |
| |
UTM
|
450kip
|
Temperature
|
no data
|
Test 4 of 30
DIME Test ID: 2019-10-16-6-4
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 10/29/2019
Date Tested: 10/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test: A490 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 3B | 051519-7EM | 1.2500 | 156897 | 697.91 | 6.00 | A490 Wedge Tensile | spaine |
| |
UTM
|
450kip
|
Temperature
|
no data
|
Test 5 of 30
DIME Test ID: 2019-10-16-6-5
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 10/29/2019
Date Tested: 10/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test: A490 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 4A | 27128-10508080 | 1.2500 | 160460 | 713.76 | 6.00 | A490 Wedge Tensile | spaine |
| |
UTM
|
450kip
|
Temperature
|
no data
|
Test 6 of 30
DIME Test ID: 2019-10-16-6-6
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 10/29/2019
Date Tested: 10/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test: A490 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 5A | 050218-1CG-60 | 1.2500 | 160995 | 716.14 | 6.00 | A490 Wedge Tensile | spaine |
| |
UTM
|
450kip
|
Temperature
|
no data
|
Test 7 of 30
DIME Test ID: 2019-10-16-6-7
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 10/29/2019
Date Tested: 10/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 1A | 30581-6214661005 | | 170147 | | Nut Proof Load | spaine |
| |
UTM
|
450kip
|
Temperature
|
72 f
|
Test 8 of 30
DIME Test ID: 2019-10-16-6-8
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 10/29/2019
Date Tested: 10/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 2A | 28846-6214661005 | | 170594 | | Nut Proof Load | spaine |
| |
UTM
|
450kip
|
Temperature
|
72 f
|
Test 9 of 30
DIME Test ID: 2019-10-16-6-9
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
050919-4FM
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
BBC A490
|
Size
|
1.25 in
|
Bolt Length
|
10 in
|
Gage Type
|
Pass
|
Test 10 of 30
DIME Test ID: 2019-10-16-6-10
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
041719-1CM
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
BBC A490
|
Size
|
1.25 in
|
Bolt Length
|
10 in
|
Gage Type
|
Pass
|
Test 11 of 30
DIME Test ID: 2019-10-16-6-11
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
051519-7EM
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
BBC A490
|
Size
|
1.25 in
|
Bolt Length
|
10 in
|
Gage Type
|
Pass
|
Test 12 of 30
DIME Test ID: 2019-10-16-6-12
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
051519-7EM
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
BBC A490
|
Size
|
1.25 in
|
Bolt Length
|
10 in
|
Gage Type
|
Pass
|
Test 13 of 30
DIME Test ID: 2019-10-16-6-13
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
27128-10508080
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
A490 USA
|
Size
|
1.25 in
|
Bolt Length
|
7 in
|
Gage Type
|
Pass
|
Test 14 of 30
DIME Test ID: 2019-10-16-6-14
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
050218-1CG-60
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
BBC A490
|
Size
|
1.25 in
|
Bolt Length
|
6 in
|
Gage Type
|
Pass
|
Test 15 of 30
DIME Test ID: 2019-10-16-6-15
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
30581-6214661005
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
DH3 U
|
Size
|
1.25 in
|
Gage Type
|
Pass
|
Test 16 of 30
DIME Test ID: 2019-10-16-6-16
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
28846-6214661005
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
DH3 U
|
Size
|
1.25 in
|
Gage Type
|
Pass
|
Test 17 of 30
DIME Test ID: 2019-10-16-6-17
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
30581-6214661005
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
DH3 U
|
Size
|
1.25 in
|
Gage Type
|
Pass
|
Test 18 of 30
DIME Test ID: 2019-10-16-6-18
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
30581-6214661005
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
DH3 U
|
Size
|
1.25 in
|
Gage Type
|
Pass
|
Test 19 of 30
DIME Test ID: 2019-10-16-6-19
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
27185-6214506106
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
DH3 U
|
Size
|
1.25 in
|
Gage Type
|
Pass
|
Test 20 of 30
DIME Test ID: 2019-10-16-6-20
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
27807-6214552009
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
DH3 U
|
Size
|
1.25 in
|
Gage Type
|
Pass
|
Test 21 of 30
DIME Test ID: 2019-10-16-6-21
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
30581-6214661005
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
DH3 U
|
Size
|
1.25 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
31.7
|
Spacing
|
Ok
|
Test 22 of 30
DIME Test ID: 2019-10-16-6-22
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
30581-6214661005
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
DH3 U
|
Size
|
1.25 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
31.12
|
Spacing
|
Ok
|
Test 23 of 30
DIME Test ID: 2019-10-16-6-23
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
27185-6214506106
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
DH3 U
|
Size
|
1.25 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
30.28
|
Spacing
|
Ok
|
Test 24 of 30
DIME Test ID: 2019-10-16-6-24
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
27807-6214552009
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
DH3 U
|
Size
|
1.25 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
29.76
|
Spacing
|
Ok
|
Test 25 of 30
DIME Test ID: 2019-10-16-6-25
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
0115-716
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
F436 TSI 3
|
Size
|
1.25 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
42
|
Spacing
|
Ok
|
Test 26 of 30
DIME Test ID: 2019-10-16-6-26
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
0115-716
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
F436 TSI 3
|
Size
|
1.25 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
42.95
|
Spacing
|
Ok
|
Test 27 of 30
DIME Test ID: 2019-10-16-6-27
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
0115-716
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
F436 TSI 3
|
Size
|
1.25 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
39.55
|
Spacing
|
Ok
|
Test 28 of 30
DIME Test ID: 2019-10-16-6-28
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
0115-716
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
F436 TSI 3
|
Size
|
1.25 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
40.9
|
Spacing
|
Ok
|
Test 29 of 30
DIME Test ID: 2019-10-16-6-29
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D3644 144
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
F436-3 P
|
Size
|
1.25 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
41.55
|
Spacing
|
Ok
|
Test 30 of 30
DIME Test ID: 2019-10-16-6-30
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/29/2019
Date Tested: 10/25/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D4851
|
Finish Coating
|
ASTM F1136 - Dachromet or Geomet
|
Product Markings
|
F436-3 P
|
Size
|
1.25 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
42.55
|
Spacing
|
Ok
|