Sample Record for 2019-06-12-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 211260 DEA: 072159U4 EFIS: 0715000160
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA,ORA-5-0.0/1.5, 44.3/44.4
Work Description: CONSTRUCT HOV LANES AND MIX FLOW LANES.
Location Description: LOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 TOWNSGATE RD. SUITE 200, WESTLAKE VILLAGE, CA 91361
Resident Engineer: George Saker Structure Rep.: Danny Lalonde
Sample Information
DIME Sample ID: 2019-06-12-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Department Acceptance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 06/12/2019
Date that the sample was received by the laboratory/organization performing the testing: 06/19/2019
The quantity of what the sample constitutes: 2
A brief description of the sample: 13x13x2.5 Elastomeric Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber
Material Information
Mfg. Lot Number(s): 17920-1
Material/Compound/Elastomer ID: 55 Duro
Samples Representing: 2
Description (size): 13x13x2.5
Comments: Unknown
Description (Number of Shims): 5
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: 17920-1
Test Results
Test 1 of 4
DIME Test ID: 2019-06-12-1-1
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 06/21/2019
Date Tested: 06/21/2019
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Test 2 of 4
DIME Test ID: 2019-06-12-1-2
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 06/26/2019
Date Tested: 06/20/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
53
|
Reading #2
|
51
|
Reading #3
|
51
|
Reading #4
|
52
|
Reading #5
|
52
|
Mean
|
51.8
|
Test 3 of 4
DIME Test ID: 2019-06-12-1-3
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 06/26/2019
Date Tested: 06/21/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2KIP
|
Humidity
|
50 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.069 in
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2485.5 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.072 in
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2666.7 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.073 in
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2513.7 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2513.7 lbf/in^2
|
Test 4 of 4
DIME Test ID: 2019-06-12-1-4
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 06/26/2019
Date Tested: 06/21/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
UTM
|
no data
|
Humidity
|
50 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.065 in
|
Sample 1 Tear Strength
|
184.6 lbf / in
|
Sample 2 Median Thickness
|
0.066 in
|
Sample 2 Tear Strength
|
181.8 lbf / in
|
Sample 3 Median Thickness
|
0.071 in
|
Sample 3 Tear Strength
|
183.1 lbf / in
|
Median of the Tear Strength Values
|
183.1 lb/in
|