Print Report | Back to Sample Detail

Sample Record for 2017-09-13-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211967 DEA: 101E8904 EFIS: 1016000093 QA Service Level: 1
DIST-CO-RTE-PM: 10-SJ-5-26.5/27.0
Work Description: REPAIR BRIDGE CROSSFRAMES.
Location Description: SAN JOAQUIN COUNTY IN STOCKTON AT STOCKTON CHANNEL VIADUCT
Contractor Name: ABHE & SVOBODA, INC.
Contractor Address: 18100 Dairy Lane, Jordan, MN 55352
Resident Engineer: Ariel Mendoza Structure Rep.: Mohsen Abdelfatah

Sample Information

DIME Sample ID: 2017-09-13-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT - Unassigned/General Field Laboratory
Sample Organization Contact: 5625005861
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 09/13/2017
Date that the sample was received by the laboratory/organization performing the testing: 09/15/2017
The quantity of what the sample constitutes: 34
A brief description of the sample: A325 Bolts
From where was the sample collected: Distributor
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cordova Bolt

Material Information

Rocap Number(s): 304 17 04
Heat Number(s): DL16100849
Nut Mfg. Lot Number(s): 385053B
Washer Mfg. Lot Number(s): 0317 495
Bolt Specification: A325
Bolt Length(s): 3-1/2
Nut Specification: A563 DH
Washer Specification: F1554
Finish: HDG
Diameter/Size: 1"
Bolt Mfg. Lot Number: 378562A
Rocap Test Requirement(s):
Lubricant Requirements(s): yes

Test Results

Test 1 of 8

DIME Test ID: 2017-09-13-1-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 09/20/2017
Date Tested: 09/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1AL02-062-171\"87291388.310A325Brian
UTM 400KIP
Temperature no data

Test 2 of 8

DIME Test ID: 2017-09-13-1-2
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 09/20/2017
Date Tested: 09/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Proof
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1AL02-062-171\"94029418.26Nut ProofBrian
UTM 400KIP
Temperature 72 F

Test 3 of 8

DIME Test ID: 2017-09-13-1-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 09/20/2017
Date Tested: 09/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 378562A
Finish Coating ASTM F2329 - Hot Dip
Product Markings A325 N
Size 1 in
Bolt Length 3.5 in
Gage Type Pass

Test 4 of 8

DIME Test ID: 2017-09-13-1-4
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 09/20/2017
Date Tested: 09/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 385053B
Finish Coating ASTM F2329 - Hot Dip
Product Markings DH N
Size 1 in
Gage Type Pass

Test 5 of 8

DIME Test ID: 2017-09-13-1-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/20/2017
Date Tested: 09/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 378562A
Finish Coating ASTM F2329 - Hot Dip
Product Markings A325 N
Size 1 in
Bolt Length 3.5 in
Measurement Average 3.27 mils

Test 6 of 8

DIME Test ID: 2017-09-13-1-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/20/2017
Date Tested: 09/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 385053B
Finish Coating ASTM F2329 - Hot Dip
Product Markings DH N
Size 1 in
Bolt Length no data in
Measurement Average 4.52 mils

Test 7 of 8

DIME Test ID: 2017-09-13-1-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/20/2017
Date Tested: 09/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 0317-495
Finish Coating ASTM F2329 - Hot Dip
Product Markings TSI F436
Size 1 in
Bolt Length no data in
Measurement Average 6.01 mils

Test 8 of 8

DIME Test ID: 2017-09-13-1-8
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 09/20/2017
Date Tested: 09/19/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 0317-495
Finish Coating ASTM F2329 - Hot Dip
Product Markings TSI F436
Size 1 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 41.05
Spacing Ok