Project ID: 993333 DEA: 04264724 EFIS: 0419000068
QA Service Level: 1
DIST-CO-RTE-PM: 04-MRN-101-R20.8/27.1
Work Description: CIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL.
Location Description: MARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE
Contractor Name: GHILOTTI CONSTRUCTION CO. INC. (RILEY GENAZZI & JOSH SERAFINO)
Contractor Address: 246 GHILOTTI AVE., SANTA ROSA, CA 95407
Resident Engineer: Fabio La Serna Structure Rep.: Jeremy Light
DIME Sample ID: 2024-05-03-66
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 206-4373
Type of Sample: Quality Assurance
Type of Material: Cementitious
Sample Taken Date: 05/03/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/06/2024
The quantity of what the sample constitutes: 6 cubes
A brief description of the sample: Grout Cubes
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 27-00900L
Structure name: Franklin Ave. OH Left Bridge
The fabricator/manufacturer/facility name: Northgate Ready Mix
DIME Test ID: 2024-05-03-66-1
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 05/31/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Set #1
Test Result Compliance:
Additional Comments When Verified:
|
Will control cubes be used per ASTM C311?
|
no
|
|
Age of specimen
|
28 days
|
|
The amount of flow
|
no data %
|
|
The amount of water used
|
100 %
|
|
Compressive strength of 1st specimen
|
7751 psi
|
|
Compressive strength of 2nd specimen
|
8159 psi
|
|
Compressive strength of 3rd specimen
|
8051 psi
|
|
Average Compressive strength (to nearest 10 psi)
|
7990 psi
|
DIME Test ID: 2024-05-03-66-2
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 05/31/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Set #2 | Specimen 2 was eliminated from the average for being outside allowable limits per Section 12 of ASTM C109.
Test Result Compliance:
Additional Comments When Verified:
|
Will control cubes be used per ASTM C311?
|
no
|
|
Age of specimen
|
28 days
|
|
The amount of flow
|
no data %
|
|
The amount of water used
|
100 %
|
|
Compressive strength of 1st specimen
|
8040 psi
|
|
Compressive strength of 2nd specimen
|
8810 psi
|
|
Compressive strength of 3rd specimen
|
8000 psi
|
|
Average Compressive strength (to nearest 10 psi)
|
8020 psi
|