Sample Record for 2024-05-06-26
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 209820 DEA: 04297634 EFIS: 0415000040 COOP: 042548
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-84,680-17.9/21
Work Description: ROUTE 84 WIDENING (4-LANE EXPRESSWAY) FROM I-680 TO PIGEON PASS, INCLUDING INTERSECTION, DRAINAGE IMPROVEMENTS AND UTILITY RELOCATION.
Location Description: ALAMEDA COUNTY IN AND NEAR SUNOL, PLEASANTON, AND LIVERMORE ON ROUTE 84 FROM 0.1 MILE EAST OF ROUTE 680 TO 0.1 MILE SOUTH OF RUBY HILL DRIVE AND ON ROUTE 680 FROM 1.2 MILES SOUTH TO 1.8 MILES NORTH OF ROUTE 84
Contractor Name: Bay Cities Paving & Grading
Contractor Address: 1450 Civic Ct. BLDG B #400, Concord CA, 94520
Resident Engineer: Paramjit Pandher Structure Rep.: Kristen We
Sample Information
DIME Sample ID: 2024-05-06-26
TL Number from the TL Form:
Sample Submitted By Organization: Harper Precast
Sample Organization Contact: (801) 326-1016
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 05/06/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/07/2024
The quantity of what the sample constitutes: 6 yds
A brief description of the sample: MSE Wall Panels
From where was the sample collected: Fabricator
Laboratory sample identification: Harper Precast Lab
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Harper Precast
Material Information
The concrete mix design number: 753030
The truck number from where the sample was collected: 40
The batch plant ticket number from where the sample was collected: 109289
Concrete batch plant: Harper Ready Mix
The fabricator/manufacturer designation for the sample: CA-49
A detailed description of where the material sample was collected: Middle third of batch from truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 1
DIME Test ID: 2024-05-06-26-1
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Submitted By Organization: Harper Precast
Organization Address: P. O. Box 18549 ,
Organization City: Salt Lake City
Organization State: UT
Organization Zipcode: 84118
Organization Email: rwinters@harperprecast.com
Organization Phone: (801) 326-1016
Data has not been verified.