Sample Record for 2021-10-06-5
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 213568 DEA: 034H6904 EFIS: 0319000026
QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC,SAC/SOL-12-0-0.4/26.3-26.4, 0.0-0.4/26.3-26.4
Work Description: Major Damage Restoration (Emergency Opening)
Location Description:
Contractor Name: Golden State Bridge, Inc.
Contractor Address: 3701 Mallard Drive, Benicia, CA 94510
Resident Engineer: Masoud Saed Structure Rep.: Chau Ha
Sample Information
DIME Sample ID: 2021-10-06-5
TL Number from the TL Form: c658234
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 10/06/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/12/2021
The quantity of what the sample constitutes: 1" F1554 anchor bolt assembly
A brief description of the sample: 1" x 7" HDG with 3" thread one end
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name: Rio Vista
The fabricator/manufacturer/facility name: CK Johnson Industries
Material Information
Rocap Number(s): none- anchor bolts
Heat Number(s): Bolt- 62150547
nut- 201945
Washer- 12108760
Nut Mfg. Lot Number(s): 34216-201945
Washer Mfg. Lot Number(s): 0521-812
Bolt Specification: F1554
Bolt Length(s): 7"
Nut Specification: A563 gr DH
Washer Specification: F436 type 1
Finish: HDG
Diameter/Size: 1"
Bolt Mfg. Lot Number: portland bolt- 62150547
Rocap Test Requirement(s): no
Lubricant Requirements(s): yes
Washer Inner Diameter(s):
Test Results
Test 1 of 8
DIME Test ID: 2021-10-06-5-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 10/28/2021
Date Tested: 10/26/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Headed F1554 10 Dea.
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
1
|
| Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments | | 1 | UNC 1 | 0.606 | 53593 | 238 | 88438 | 72576 | 43981 | Headed F1554 10 Dea. |
| |
|
UTM
|
400kip
|
|
Temperature
|
72
|
Test 2 of 8
DIME Test ID: 2021-10-06-5-2
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 10/28/2021
Date Tested: 10/26/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A536
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
1
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | | 1 | 34216-201945 | | 94283 | | A536 | fsaylor |
| |
|
UTM
|
450kip
|
|
Temperature
|
72 f
|
Test 3 of 8
DIME Test ID: 2021-10-06-5-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/28/2021
Date Tested: 10/26/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
62150547
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
PB AB55
|
|
Size
|
1 in
|
|
Bolt Length
|
7 in
|
|
Gage Type
|
Pass
|
Test 4 of 8
DIME Test ID: 2021-10-06-5-4
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 10/28/2021
Date Tested: 10/26/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
34216-201945
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
U DH
|
|
Size
|
1 in
|
|
Gage Type
|
Pass
|
Test 5 of 8
DIME Test ID: 2021-10-06-5-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/28/2021
Date Tested: 10/26/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
62150547
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
PB AB55
|
|
Size
|
1 in
|
|
Bolt Length
|
7 in
|
|
Measurement Average
|
4.97 mils
|
Test 6 of 8
DIME Test ID: 2021-10-06-5-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/28/2021
Date Tested: 10/26/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
34216-201945
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
U DH
|
|
Size
|
1 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3.77 mils
|
Test 7 of 8
DIME Test ID: 2021-10-06-5-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/28/2021
Date Tested: 10/26/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
0521-812
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
TIS F436
|
|
Size
|
1 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
4.99 mils
|
Test 8 of 8
DIME Test ID: 2021-10-06-5-8
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 10/28/2021
Date Tested: 10/26/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
0521-812
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
TIS F436
|
|
Size
|
1 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
39
|
|
Spacing
|
Ok
|