Print Report | Back to Sample Detail

Sample Record for 2019-04-01-31

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212753 DEA: 020H7604 EFIS: 0215000086 QA Service Level: 1
DIST-CO-RTE-PM: 02-LAS,PLU-VAR-VAR
Work Description: FULL DEPTH RECLAMATION AND DRAINAGE REHABILITATION
Location Description: LASSEN AND PLUMAS COUNTIES AT AND NEAR CHILCOOT FROM 0.9 MILE WEST OF SUMMIT SCHOOL DRIVE TO 0.7 MILE EAST OF ROUTE 395
Contractor Name: HAT CREEK CONSTRUCTION & MATERIALS, INC.
Contractor Address: 24339 HWT 89, BURNEY, CA 96013
Resident Engineer: Ron Collins Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-04-01-31
TL Number from the TL Form:
Sample Submitted By Organization: CGI Technical Services, Incorporated
Sample Organization Contact: (530) 244-6277
Type of Sample: Quality Control
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/01/2019
Date that the sample was received by the laboratory/organization performing the testing: 04/01/2019
The quantity of what the sample constitutes: Mix Design
A brief description of the sample: HMA Lab Batch - Mix Design
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hat Creek - Ward Lake

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: Unknown
Sublot number: Unknown
HMA Mix Number:
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test

DIME Test ID: 2019-04-01-31-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 05/08/2019
Date Tested: 05/01/2019
Submitted By Organization: CGI Technical Services, Incorporated
Organization Address: 1612 Insight Place,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96003
Organization Email: vkyatham@currygroup.com
Organization Phone: (530) 244-6277
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Percent Air Voids 4.1 %
Percent Air Voids 2 3.9 %
Percent Air Voids 3 4.1 %
Average Percent Air Voids 4 %

Test

DIME Test ID: 2019-04-01-31-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Submitted By Organization: CGI Technical Services, Incorporated
Organization Address: 1612 Insight Place,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96003
Organization Email: vkyatham@currygroup.com
Organization Phone: (530) 244-6277
This test has been superseded on 05/08/2019.
Reason: retested

Test

DIME Test ID: 2019-04-01-31-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/08/2019
Date Tested: 05/01/2019
Submitted By Organization: CGI Technical Services, Incorporated
Organization Address: 1612 Insight Place,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96003
Organization Email: vkyatham@currygroup.com
Organization Phone: (530) 244-6277
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 5.4 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data

Test

DIME Test ID: 2019-04-01-31-5
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/08/2019
Date Tested: 05/01/2019
Submitted By Organization: CGI Technical Services, Incorporated
Organization Address: 1612 Insight Place,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96003
Organization Email: vkyatham@currygroup.com
Organization Phone: (530) 244-6277
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Specific Gravity for Sample 1 2.392
Theoretical maximum density at 25°C (77°F) no data

Test

DIME Test ID: 2019-04-01-31-6
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 05/08/2019
Date Tested: 05/03/2019
Submitted By Organization: CGI Technical Services, Incorporated
Organization Address: 1612 Insight Place,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96003
Organization Email: vkyatham@currygroup.com
Organization Phone: (530) 244-6277
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity 2.286
Bulk Specific Gravity 2 2.289
Bulk Specific Gravity 3 2.289
Average Bulk Specific Gravity 2.288

Test

DIME Test ID: 2019-04-01-31-7
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Submitted By Organization: CGI Technical Services, Incorporated
Organization Address: 1612 Insight Place,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96003
Organization Email: vkyatham@currygroup.com
Organization Phone: (530) 244-6277
Data has not been verified.