Print Report | Back to Sample Detail

Sample Record for 2026-01-20-12

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 99999 DEA: 0322222 QA Service Level:
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Michael Maksimovich Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-01-20-12
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Materials Management Branch Field Office
Sample Organization Contact: (562) 500-5861
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 01/20/2026
Date that the sample was received by the laboratory/organization performing the testing: 01/20/2026
The quantity of what the sample constitutes: 90 CY
A brief description of the sample: Concrete Test Samples
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex

Material Information

The concrete mix design number: 12345678
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 1855
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2026-01-20-12-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 01/20/2026
Date Tested: 01/20/2026
Submitted By Organization: CT HQ - Sacramento Materials Management Branch Field Office
Organization Address: 5900 Folsom Boulevard, MS 5,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brett.soldano@dot.ca.gov
Organization Phone: (562) 500-5861
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 1
Test performed With no density determined
Capped in accordance with? ASTM C39 - Ground End
Apparent mass of submerged cylinder 1 10 lb
Average diameter of cylinder 1 5.89 in
Compressive strength of cylinder (to nearest 10 psi) 2100 psi
Maximum load on cylinder 1 320 lb
Type of fracture pattern of cylinder 1 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Age of specimen 7 days
Age of specimen in hours 168 hours
Serial number of delivery ticket, if available no data

Test 2 of 2

DIME Test ID: 2026-01-20-12-2
Test Method: CTM 342C-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)
Submitted By Organization: CT HQ - Sacramento Materials Management Branch Field Office
Organization Address: 5900 Folsom Boulevard, MS 5,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brett.soldano@dot.ca.gov
Organization Phone: (562) 500-5861
Data has not been verified.