Summary for Test 2020-10-28-13-4
Test performed: CTM 214-August 2010Project Information
Project Identifiers | Project ID: 213568 DEA: 034H6904 EFIS: 0319000026 |
---|---|
DIST-CO-RTE-PM | 03-SAC,SAC/SOL-12-0-0.4/26.3-26.4, 0.0-0.4/26.3-26.4 |
Award Date | 08/13/2018 |
Closeout Date | 08/28/2023 |
Work Description | Major Damage Restoration (Emergency Opening) |
Location Description | Not set |
QA Service Level | 1 (Verified on 08/24/2018) |
Sample Information
Sample Taken Date | 10/28/2020 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/29/2020 |
Sample type | Quality Assurance | A brief description of the sample | Hydrolite-Trinity Lightweight |
The quantity of what the sample constitutes | 3-5 gallon bucket | From where was the sample collected | Job Site |
First name of sampler or witnessed by | not available | Last name of sampler or witnessed by | not available |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 20-PCCC-0217 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | na | Transportation Laboratory (TL) Number | na |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | na |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | at job site | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-10-28-13
DIME Test ID: 2020-10-28-13-4
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2020-12-07
Test Results
What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: RK/JH
Date of test: 12/07/2020
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: no data
Percentage Loss of material retained on ¾ x ½ in. sieve: no data
Percentage Loss of material retained on ½ x ⅜ in. sieve: no data
Percentage Loss of material retained on ⅜ in. x #4 sieve: no data
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 2.0 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/7/2020 ✔