Summary for Test 2020-11-13-8-2

Test performed: AASHTO T335-09r13

Project Information

Project IdentifiersProject ID: 214340
DEA: 081G2914
EFIS: 0818000114
DIST-CO-RTE-PM08-SBD-10-27.9
Award Date05/22/2020
Closeout Date11/01/2021
Work DescriptionWIDEN EB OFF RAMP
Location DescriptionSAN BERNARDINO COUNTY IN REDLANDS AT CALIFORNIA STREET EASTBOUND EXIT RAMP
QA Service Level1 (Verified on 07/16/2020)

Sample Information

Sample Taken Date11/13/2020 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/16/2020
Sample typeVerification A brief description of the sampleJMF 3/4" RWMA-G-SP, 0.5% Evotherm
The quantity of what the sample constitutes2 Bags of Coldfeed Aggregate From where was the sample collectedManufacturer
First name of sampler or witnessed byR J Noble Company Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0668G-20 Linked DIME Sample ID
The fabricator/manufacturer/facility nameR J Noble Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0014, 91-33-0039
The fabricator's/manufacturer's product name for the sample3/4 RWMA-G-SP The fabricator/manufacturer designation for the sample
The plant number49R003ARSPWEC A detailed description of where the material sample was collectedBelt Cut at RJ Noble Corona Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-11-13-8
DIME Test ID: 2020-11-13-8-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2020-12-01

Test Results


Method: 2 - Individual Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced and Fine 1 Faced
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 11/21/2020
Weighted average percentage of fractured, coarse, 2 faced particles: 99 %
Weighted average percentage of fractured, coarse, 1 faced particles: 100 %
Percentage of fractured, fine, 1 faced particles tested: 100 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/1/2020