Summary for Test 2020-10-13-30-1

Test performed: CTM 643-April 2020

Project Information

Project IdentifiersProject ID: 215304
DEA: 010E0814
EFIS: 0118000172
DIST-CO-RTE-PM01-LAK-20,29,175-Var
Award Date09/20/2021
Closeout DateNot set
Work DescriptionReplace & widen bridges
Location DescriptionLAKE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 11/04/2020)

Sample Information

Sample Taken Date10/13/2020 Sample Unique Key30
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/09/2020
Sample typePer Request A brief description of the sampleNative soil
The quantity of what the sample constitutes110.77 From where was the sample collectedJob Site
First name of sampler or witnessed byS Last name of sampler or witnessed byAwad
Title of samplerTransportation Engineer Telephone number of sampler925-864-1069
Laboratory sample identificationCR20200482 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCaltrans Transportation Laboratory (TL) NumberC002410
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier01-LAK-29-PM50.82
Structure nameRobinson Creek Bridge

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleSoil Foundation RC-20-002
The fabricator/manufacturer designation for the sampleNative Soil A detailed description of where the material sample was collected22-25 feet depth Br 14-0030
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2020-10-13-30
DIME Test ID: 2020-10-13-30-1
Testing Lab: Wood
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-11-12

Test Results


The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Calculated
Tester's full name: Michael Gibson
Date of test: 11/10/2020
Minimum soil resistance of the lab measurement: 470 Ohms
Soil sample temperature: 21.9 C
Soil box constant: 1
pH of soil: 7.77
Minimum soil resistance corrected to 15.5: 545.00 Ohm-cm
Minimum soil resistivity at 15.5: 545 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/12/2020