Summary for Test 2020-10-22-3-1
Test performed: ASTM A370-15Project Information
Project Identifiers | Project ID: 77777 DEA: CHEM-STOCK EFIS: CHEM-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 10/22/2020 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/03/2020 |
Sample type | Quality Assurance | A brief description of the sample | 3"-4 x 60" ASTM F1554-15 Gr. 55=S1 D.E. Stud |
The quantity of what the sample constitutes | 1 of 25 | From where was the sample collected | Source |
First name of sampler or witnessed by | Daniel | Last name of sampler or witnessed by | Reyes |
Title of sampler | CT QA METS Inspector | Telephone number of sampler | (707) 656-9086 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CMC Steel | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B301-018-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 3094722 | Nut Mfg. Lot Number(s) | XSF2 |
Washer Mfg. Lot Number(s) | 3326 | Bolt Specification | ASTM F1554-15 Gr. 55-S1 |
Bolt Length(s) | 60" | Nut Specification | ASTM A194-14a Grade 2H |
Washer Specification | F436 S | Finish | HDG |
Diameter/Size | 3" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2020-10-22-3
DIME Test ID: 2020-10-22-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2020-11-09
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 11/06/2020
UTM: 67kip
Temperature: 72 f
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 3094722 | 0.504 | 0.2 | 66591 | 92928 | 26.4 | fsaylor |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 11/9/2020 ✔