Summary for Test 2020-11-03-2-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 214922
DEA: 100X3104
EFIS: 1013000265
DIST-CO-RTE-PM10-SJ-99-16.8/17.6
Award Date06/30/2020
Closeout Date04/07/2022
Work DescriptionREPLACE BRIDGE.
Location DescriptionSAN JOAQUIN COUNTY IN STOCKTON FROM 0.4 MILE SOUTH TO 0.4 MILE NORTH OF FARMINGTON ROAD OVERCROSSING
QA Service Level1 (Verified on 04/28/2020)

Sample Information

Sample Taken Date11/03/2020 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/06/2020
Sample typeQuality Assurance A brief description of the sample#7 flash welded hoops 3'-8" Dia
The quantity of what the sample constitutes124 From where was the sample collectedFabricator
First name of sampler or witnessed bySteve Last name of sampler or witnessed byHall
Title of samplerCT METS QA INSPECTOR Telephone number of sampler6466327821
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar Etiwanda Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL134-259-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4100630
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size#7
Diameter of Hoop3'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Arizona
Welding CompanyCMC Rebar Etiwanda Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2020-11-03-2
DIME Test ID: 2020-11-03-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2020-11-06

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 11/06/2020
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1117/22mm0.661701.64102836OK Neckingfsaylor

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 11/6/2020