Summary for Test 2020-11-03-2-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 214922 DEA: 100X3104 EFIS: 1013000265 |
---|---|
DIST-CO-RTE-PM | 10-SJ-99-16.8/17.6 |
Award Date | 06/30/2020 |
Closeout Date | 04/07/2022 |
Work Description | REPLACE BRIDGE. |
Location Description | SAN JOAQUIN COUNTY IN STOCKTON FROM 0.4 MILE SOUTH TO 0.4 MILE NORTH OF FARMINGTON ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 04/28/2020) |
Sample Information
Sample Taken Date | 11/03/2020 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/06/2020 |
Sample type | Quality Assurance | A brief description of the sample | #7 flash welded hoops 3'-8" Dia |
The quantity of what the sample constitutes | 124 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Steve | Last name of sampler or witnessed by | Hall |
Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 6466327821 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CMC Rebar Etiwanda | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L134-259-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4100630 |
Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #7 |
Diameter of Hoop | 3'-8" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC Arizona |
Welding Company | CMC Rebar Etiwanda | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2020-11-03-2
DIME Test ID: 2020-11-03-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2020-11-06
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 11/06/2020
UTM: 400kip
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 1 | 7/22mm | 0.6 | 61701.64 | 102836 | OK Necking | fsaylor |
General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 11/6/2020 ✔