Summary for Test 2020-10-24-5-4

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 215201
DEA: 080G9204
EFIS: 0818000194
DIST-CO-RTE-PM08-SBD-18-94.2
Award Date09/01/2020
Closeout DateNot set
Work DescriptionWiden RTE 18 TO 6 Lanes, Realign &Widen
Location DescriptionApple Valley Road
QA Service Level2 (Verified on 10/02/2020)

Sample Information

Sample Taken Date10/24/2020 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/28/2020
Sample typeVerification A brief description of the sampleJMF 3/4" HMA-A-SP R15, 0.6% LAS
The quantity of what the sample constitutes4 Bags Of Coldfeed Agg., 2 Bags Of Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byAlex Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0638A-20 Linked DIME Sample ID
The fabricator/manufacturer/facility nameBlue Diamond Materials-Victorville Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0046, 91-36-0106
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number300154 A detailed description of where the material sample was collectedBelt Cut at Blue Diamond Victorville Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-10-24-5
DIME Test ID: 2020-10-24-5-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2020-11-16

Test Results


Input Type: Measured
Tester's full name: Friday Ofoegbu
Date of test: 11/03/2020
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 967.3 grams
Mass of the pycnometer with water (B): 653.3 grams
Mass of the oven dried sample (before pycnometer) (A): 491.4 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 491.4 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.642
Bulk specific gravity (SSD Basis): 2.688
Apparent specific gravity: 2.770
Absorption: 1.8 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/16/2020