Summary for Test 2020-10-08-7-16

Test performed: ASTM B499-14

Project Information

Project IdentifiersProject ID: 214175
DEA: 030H4804
EFIS: 0315000198
DIST-CO-RTE-PM03-SAC-99-0.1/1.6,11.8/21.6
Award Date08/20/2019
Closeout Date08/11/2023
Work DescriptionCOLD PLANE AC PAVEMENT AND RHMA OVERLAY.
Location DescriptionSACRAMENTO COUNTY IN AND NEAR GALT FROM DRY CREEK BRIDGE TO SIMMERHORN ROAD AND IN ELK GROVE AND SACRAMENTO FROM 0.9 MILE SOUTH OF ELK GROVE BOULEVARD TO MARTIN LUTHER KING JR BOULEVARD
QA Service Level1 (Verified on 05/29/2019)

Sample Information

Sample Taken Date10/08/2020 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/20/2020
Sample typeQuality Assurance A brief description of the sample1/2-13 X 1 1/4 A325 Hvy Hex Bolt
The quantity of what the sample constitutes52 From where was the sample collectedFabricator
First name of sampler or witnessed byRoland Last name of sampler or witnessed byMaynard
Title of samplerQA Telephone number of sampler(510) 774-1269
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameStructural and Steel Products Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)091620A
Heat Number(s)100792173 Nut Mfg. Lot Number(s)414845B
Washer Mfg. Lot Number(s)D9266 Bolt SpecificationA325
Bolt Length(s)1 1/4" Nut SpecificationA563
Washer SpecificationF436 FinishMG
Diameter/Size1/2" Bolt Mfg. Lot Number406819A
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2020-10-08-7
DIME Test ID: 2020-10-08-7-16
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2020-10-27

Test Results


Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 10/22/2020
Sample No.: 1C
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: D9266
Finish Coating: ASTM B695 - Mech Galv
Product Markings: F436 P
Size: .5 in
Bolt Length: no data
Measurement Average: 3.38 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/27/2020