Summary for Test 2020-10-16-1-1
Test performed: AASHTO T27-14Project Information
Project Identifiers | Project ID: 213306 DEA: 07303404 EFIS: 0714000006 |
---|---|
DIST-CO-RTE-PM | 07-VEN-33-0.0/6.3 |
Award Date | 06/18/2018 |
Closeout Date | 05/10/2021 |
Work Description | COLD PLANE AC PVMT, PLACE RUBBERIZED AC (TYPE G), AND REPLACE PCC PVMT |
Location Description | VENTURA COUNTY IN AND NEAR VENTURA FROM ROUTE 33/101 SEPARATION TO 0.1 MILE SOUTH OF PARK VIEW DRIVE |
QA Service Level | 1 (Verified on 12/09/2020) |
Sample Information
Sample Taken Date | 10/16/2020 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/17/2020 |
Sample type | Verification | A brief description of the sample | PSUE 3/4" HMA-A-SP R15 |
The quantity of what the sample constitutes | 5 Bags Of Agg., 1 Bag Of Rap | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | MD | Last name of sampler or witnessed by | Shajahan |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0612A-20 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Sun Valley | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0035::FISH CANYON QUARRY |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 3/4 HMA-A-SP R15 | The fabricator/manufacturer designation for the sample | |
The plant number | 220831 SVA MPC | A detailed description of where the material sample was collected | Belt Cut at Vulcan Sun Valley Plant |
Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-10-16-1
DIME Test ID: 2020-10-16-1-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-10-26
Test Results
What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Satish Jain/ Sebastian Ferrer
Date of test: 10/19/2020
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 99 %
Cumulative percent passing the 1/2 in. sieve: 82 %
Cumulative percent passing the 3/8 in. sieve: 62 %
Cumulative percent passing the #4 sieve: 45 %
Cumulative percent passing the #8 sieve: 29 %
Cumulative percent passing the #16 sieve: 19 %
Cumulative percent passing the #30 sieve: 12 %
Cumulative percent passing the #50 sieve: 7 %
Cumulative percent passing the #100 sieve: 4 %
Cumulative percent passing the #200 sieve: 2.3 %
General comments (publicly viewable) (Max 1000 characters): Combined Virgin Aggregate Gradation
Test was verified on 10/26/2020 ✔