Summary for Test 2020-10-12-11-6
Test performed: AASHTO T176-08Project Information
Project Identifiers | Project ID: 214848 DEA: 081H3414 EFIS: 0818000172 |
---|---|
DIST-CO-RTE-PM | 08-SBD-210,215,259-Various |
Award Date | 05/07/2020 |
Closeout Date | 10/13/2022 |
Work Description | PLACE RHMA-G, COLD PLANE AC AND REPLACE AC SURFACING. |
Location Description | SAN BERNARDINO COUNTY ON ROUTE 210, 215 AND 259 AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 07/20/2020) |
Sample Information
Sample Taken Date | 10/12/2020 | Sample Unique Key | 11 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/13/2020 |
Sample type | Verification | A brief description of the sample | PSUE 3/4" HMA-A-SP R15 No LAS |
The quantity of what the sample constitutes | 4 Bags Coldfeed Agg., 2 Bags Rap | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Cezar | Last name of sampler or witnessed by | All American Asphalt QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0594A-20 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | All American Asphalt - Corona | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0005 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 3/4 HMA-A-SP R15 | The fabricator/manufacturer designation for the sample | |
The plant number | 105927 | A detailed description of where the material sample was collected | Belt Cut at All American Corona Plant |
Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-10-12-11
DIME Test ID: 2020-10-12-11-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2020-10-19
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Larry Diaz
Date of test: 10/17/2020
Clay Level (Test 1): 5.6
Sand Level (Test 1): 3.8
Clay Level (Test 2): 5.7
Sand Level (Test 2): 3.9
Clay Level (Test 3): 5.6
Sand Level (Test 3): 3.7
Sand Equivalent (Test 1): 68
Sand Equivalent (Test 2): 69
Sand Equivalent (Test 3): 67
Sand Equivalent: 68
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/19/2020 ✔