Summary for Test 2020-07-15-54-4

Test performed: CONCLP 4-16

Project Information

Project IdentifiersProject ID: 214625
DEA: 120R5404
EFIS: 1218000113
DIST-CO-RTE-PM12-ORA-5-1.6/33.1
Award Date02/27/2020
Closeout Date07/29/2021
Work DescriptionMethacrylate deck seal treatment and polyester concrete overlay
Location DescriptionFOR CONSTRUCTION ON STATE HIGHWAY IN ORANGE COUNTY AT VARIOUS LOCATIONS FROM EL CAMINO REAL UNDERCROSSING TO MAIN STREET OVERCROSSING
QA Service Level1 (Verified on 06/16/2020)

Sample Information

Sample Taken Date07/15/2020 Sample Unique Key54
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/15/2020
Sample typeQuality Control A brief description of the sample2 pints 204,chp,zcure,8020
The quantity of what the sample constitutes25000 gallons From where was the sample collectedSource
First name of sampler or witnessed byDaniel Last name of sampler or witnessed byTikusis
Title of samplerTechnical Director Telephone number of sampler7073309227
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeMethacrylate Mfg. Lot Number(s)2070490589
Batch number2070490589 Mix number2070490589

Test Details

DIME Sample ID: 2020-07-15-54
DIME Test ID: 2020-07-15-54-4
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2020-10-16

Test Results


Input Type: Calculated
Tester's full name: Larry McCrum
Date of test: 10/16/2020
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 20
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.09
Volatile content (ASTM D 2369) 30% max: 18.45
Flash point (ASTM D 3828) more than 180 deg F: 225
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 824
Tack free time, 400 minutes max: 325
General comments (publicly viewable) (Max 1000 characters): Bond Strength and Tack Free are suppliers results

Test was verified on 10/16/2020