Summary for Test 2020-07-15-54-4
Test performed: CONCLP 4-16Project Information
Project Identifiers | Project ID: 214625 DEA: 120R5404 EFIS: 1218000113 |
---|---|
DIST-CO-RTE-PM | 12-ORA-5-1.6/33.1 |
Award Date | 02/27/2020 |
Closeout Date | 07/29/2021 |
Work Description | Methacrylate deck seal treatment and polyester concrete overlay |
Location Description | FOR CONSTRUCTION ON STATE HIGHWAY IN ORANGE COUNTY AT VARIOUS LOCATIONS FROM EL CAMINO REAL UNDERCROSSING TO MAIN STREET OVERCROSSING |
QA Service Level | 1 (Verified on 06/16/2020) |
Sample Information
Sample Taken Date | 07/15/2020 | Sample Unique Key | 54 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/15/2020 |
Sample type | Quality Control | A brief description of the sample | 2 pints 204,chp,zcure,8020 |
The quantity of what the sample constitutes | 25000 gallons | From where was the sample collected | Source |
First name of sampler or witnessed by | Daniel | Last name of sampler or witnessed by | Tikusis |
Title of sampler | Technical Director | Telephone number of sampler | 7073309227 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia | Transportation Laboratory (TL) Number | Sacramento Caltrans lab |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Methacrylate | Mfg. Lot Number(s) | 2070490589 |
---|---|---|---|
Batch number | 2070490589 | Mix number | 2070490589 |
Test Details
DIME Sample ID: 2020-07-15-54
DIME Test ID: 2020-07-15-54-4
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2020-10-16
Test Results
Input Type: Calculated
Tester's full name: Larry McCrum
Date of test: 10/16/2020
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 20
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.09
Volatile content (ASTM D 2369) 30% max: 18.45
Flash point (ASTM D 3828) more than 180 deg F: 225
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 824
Tack free time, 400 minutes max: 325
General comments (publicly viewable) (Max 1000 characters): Bond Strength and Tack Free are suppliers results
Test was verified on 10/16/2020 ✔