Summary for Test 2020-06-16-53-3
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 215240 DEA: 021H6804 EFIS: 0216000010 |
---|---|
DIST-CO-RTE-PM | 02-TEH-5-39/41.9 |
Award Date | 02/13/2023 |
Closeout Date | Not set |
Work Description | SB Cottonwood Scales |
Location Description | Not set |
QA Service Level | 1 (Verified on 10/23/2020) |
Sample Information
Sample Taken Date | 06/16/2020 | Sample Unique Key | 53 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/16/2020 |
Sample type | Informational | A brief description of the sample | Sand, silt, Rock, Rap |
The quantity of what the sample constitutes | not provided | From where was the sample collected | Job Site |
First name of sampler or witnessed by | B | Last name of sampler or witnessed by | Steiner |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D78484 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Not Provided | Transportation Laboratory (TL) Number | 824579 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA or name of Pit) | Not Applicable |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | SB Cottonwood Truck Scales near fence line | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1-1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-06-16-53
DIME Test ID: 2020-06-16-53-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-10-19
Test Results
The test method used?: Laboratory Resistivity Test for Soil
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 06/24/2020
Minimum soil resistance of the lab measurement: 4100 Ohms
Soil sample temperature: 20.3 C
Soil box constant: 1
pH of soil: 5.66
Minimum soil resistance corrected to 15.5: 4592.00 Ohm-cm
Minimum soil resistivity at 15.5: 4592 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/19/2020 ✔