Summary for Test 2020-06-16-53-3

Test performed: CTM 643-April 2020

Project Information

Project IdentifiersProject ID: 215240
DEA: 021H6804
EFIS: 0216000010
DIST-CO-RTE-PM02-TEH-5-39/41.9
Award Date02/13/2023
Closeout DateNot set
Work DescriptionSB Cottonwood Scales
Location DescriptionNot set
QA Service Level1 (Verified on 10/23/2020)

Sample Information

Sample Taken Date06/16/2020 Sample Unique Key53
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/16/2020
Sample typeInformational A brief description of the sampleSand, silt, Rock, Rap
The quantity of what the sample constitutesnot provided From where was the sample collectedJob Site
First name of sampler or witnessed byB Last name of sampler or witnessed bySteiner
Title of sampler Telephone number of sampler
Laboratory sample identificationD78484 Linked DIME Sample ID
The fabricator/manufacturer/facility nameNot Provided Transportation Laboratory (TL) Number824579
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Not Applicable
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedSB Cottonwood Truck Scales near fence line
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1-1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-06-16-53
DIME Test ID: 2020-06-16-53-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-10-19

Test Results


The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 06/24/2020
Minimum soil resistance of the lab measurement: 4100 Ohms
Soil sample temperature: 20.3 C
Soil box constant: 1
pH of soil: 5.66
Minimum soil resistance corrected to 15.5: 4592.00 Ohm-cm
Minimum soil resistivity at 15.5: 4592 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/19/2020