Summary for Test 2020-10-02-1-1
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 214393 DEA: 101C6204 EFIS: 1015000001 |
---|---|
DIST-CO-RTE-PM | 10-SJ,MPA,MER,SBT,SJ,SCL-5,88,99,104,120,etc.-15.69/29.56 |
Award Date | 02/06/2020 |
Closeout Date | 07/15/2021 |
Work Description | MODIFY ELECTRICAL SYSTEMS, INSTALL CAMERA SYSTEMS AND PLACE HMA. |
Location Description | AMADOR, MARIPOSA, MERCED, SAN BENITO, SAN JOAQUIN, AND SANTA CLARA COUNTIES AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 09/13/2019) |
Sample Information
Sample Taken Date | 10/02/2020 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/02/2020 |
Sample type | Quality Assurance | A brief description of the sample | Anchor Bolt Hardware 7/8"x17.5 A449 |
The quantity of what the sample constitutes | 637 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Lund |
Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 1-385-447-0624 |
Laboratory sample identification | na | Linked DIME Sample ID | na |
The fabricator/manufacturer/facility name | Universal Industrial Sales | Transportation Laboratory (TL) Number | na |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B390--023-20 | Structure unique identifier | |
Structure name | na |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | na |
---|---|---|---|
Heat Number(s) | 20695270 | Nut Mfg. Lot Number(s) | na |
Washer Mfg. Lot Number(s) | na | Bolt Specification | A449 Heavy Hex Bolt |
Bolt Length(s) | 17 1/2" | Nut Specification | na |
Washer Specification | na | Finish | Hot Dip Galvanize |
Diameter/Size | 7/8" | Bolt Mfg. Lot Number | 33324 |
Rocap Test Requirement(s) | na | Lubricant Requirements(s) | na |
Test Details
DIME Sample ID: 2020-10-02-1
DIME Test ID: 2020-10-02-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2020-10-12
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/08/2020
UTM: 400kip
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1A | UNC 7/8 | 0.462 | 60323 | 268 | 130569 | 117628 | 54344 | A449 Headed Bolt |
General comments (publicly viewable) (Max 1000 characters): A449 Headed Bolt
Test Graph
Source: Bluehill Data Point FileTest was verified on 10/12/2020 ✔