Summary for Test 2020-09-18-17-1

Test performed: ASTM F606-14

Project Information

Project IdentifiersProject ID: 210673
DEA: 042640F4
EFIS: 0400020132
COOP: 042308A3
DIST-CO-RTE-PM04-SON--
Award Date08/08/2019
Closeout Date02/16/2024
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 04/11/2022)

Sample Information

Sample Taken Date09/18/2020 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/18/2020
Sample typeQuality Assurance A brief description of the sample7/8" x 6 F1554 Gr 105 Hex Bolt HGD
The quantity of what the sample constitutes75 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byLund
Title of samplerCT METS QA INSPECTOR Telephone number of sampler385-447-0624
Laboratory sample identificationna Linked DIME Sample IDna
The fabricator/manufacturer/facility nameUniversal Industrial Sales Transportation Laboratory (TL) Numberna
Inspector Lot Number from the Transportation Laboratory (TL) FormB390-015-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)na
Heat Number(s)1065200 Nut Mfg. Lot Number(s)na
Washer Mfg. Lot Number(s)na Bolt SpecificationF1554 Gr 105
Bolt Length(s)6" Nut Specificationna
Washer Specificationna FinishHDG
Diameter/Size7/8 Bolt Mfg. Lot NumberW33444
Rocap Test Requirement(s)na Lubricant Requirements(s)na

Test Details

DIME Sample ID: 2020-09-18-17
DIME Test ID: 2020-09-18-17-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2020-10-08

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/08/2020
UTM: 400kip
Temperature: 72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
11AUNC 7/8 0.4626081827013164012730958817F1554 Grade 105

General comments (publicly viewable) (Max 1000 characters): F1554 Grade 105
Test Graph
Source: Bluehill Data Point File

Test was verified on 10/8/2020