Summary for Test 2020-09-22-18-3

Test performed: ASTM A970-15e1

Project Information

Project IdentifiersProject ID: 208973
DEA: 120H1004
EFIS: 1200000180
COOP: 120670
DIST-CO-RTE-PM12-ORA-405,73,405,605-9.3/24.3
Award Date11/07/2016
Closeout DateNot set
Work Description(Alternative Delivery) San Diego Freeway (I-405) Improvement Project SR-73 to I-605, Design Build Project, Administered by Orange County Transportation Authority, Caltrans METS to perform Source Inspection per RFP.
Location DescriptionOrange and Los Angeles Counties: 12-ORA-405 PM 9.3/24.2 / 07-LA-405 PM 0.0/1.2 12-ORA-22 PM R0.7/R3.8 / 12-ORA-22 PM R0.5/R0.7 12-ORA-73 PM R27.2/R27.8 / 12-ORA-605 PM 3.5/R1.6 07-LA-605 PM R0.0/R1.2
QA Service Level1 (Verified on 09/10/2015)

Sample Information

Sample Taken Date09/22/2020 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/29/2020
Sample typeQuality Assurance A brief description of the sampleWiiliams End Anchor Heads
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byS Last name of sampler or witnessed byFIERRO
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameWilliams Form Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)100896835 Head Manufacturer Lot Number(s)Unknown
Rebar Size#7 Headed Bar Model NameUnknown
Size of HeadFull Size - 9x Head Connection TypeThreaded
Head ShapeSquare Rebar ManufacturerWilliams threaded bar
Head ManufacturerUnknown Head FabricatorUnknown
Material Standard CodeASTM A615 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2020-09-22-18
DIME Test ID: 2020-09-22-18-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2020-10-06

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/06/2020
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
110.65507291787Williams End Anchor Head Broke offfsaylor

General comments (publicly viewable) (Max 1000 characters): Williams End Anchor Head Broke off
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 10/6/2020