Summary for Test 2020-09-28-35-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214775
DEA: 081F13U4
EFIS: 0819000074
DIST-CO-RTE-PM08-SBD-62,95-122.0/142.7,9.7/33.6
Award Date05/04/2020
Closeout Date06/30/2021
Work DescriptionCOLD-IN PLACE RECYCLING AND PLACE RHMA-G.
Location DescriptionSAN BERNARDINO COUNTY ON ROUTE 62 FROM 3.8 MILES WEST OF ROUTE 95 TO ARIZONA STATE LINE AND ON ROUTE 95 FROM ROUTE 62 TO 2.0 MILES SOUTH OF TURTLE MOUNTAIN ROAD
QA Service Level1 (Verified on 08/14/2020)

Sample Information

Sample Taken Date09/28/2020 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/01/2020
Sample typeDepartment Acceptance A brief description of the sample1/2" RHMA-G PG 64-16RB (0.5% LAS)
The quantity of what the sample constitutes2 boxes 285.0 tons out From where was the sample collectedManufacturer
First name of sampler or witnessed byQC Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0565G-20 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Construction Company- Indio Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number1
Sublot number18 HMA Mix NumberNot set

Combined Gradation Report Information

Combined Gradation Report IdBin IndexDime Test Id
No assigned tests for this sample.

Test Details

DIME Sample ID: 2020-09-28-35
DIME Test ID: 2020-09-28-35-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-10-02

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Angelito Villegas
Date of test: 10/01/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: no data g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data %
Moisture Content: no data %
Temperature Compensation Factor: no data
Test Temperature: no data F
Corrected Asphalt Binder Content: 7.75 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/2/2020