Summary for Test 2020-09-23-15-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 214228 DEA: 120N4904 EFIS: 1214000050 |
---|---|
DIST-CO-RTE-PM | 12-ORA-91-R12.5/R13.9 |
Award Date | 11/29/2022 |
Closeout Date | 11/07/2023 |
Work Description | VEHICLE ENFORCEMENT FACILITY IMPROVEMENT AT PERALTA WEIGH STATION. |
Location Description | ORANGE COUNTY IN ANAHEIM FROM 1.0 MILE EAST OF ROUTE 91/90 SEPARATION TO 0.5 MILE WEST OF WEIR CANYON ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 08/13/2019) |
Sample Information
Sample Taken Date | 09/23/2020 | Sample Unique Key | 15 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/28/2020 |
Sample type | Quality Assurance | A brief description of the sample | 1 1/4" HHN HDG |
The quantity of what the sample constitutes | 80 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Steve | Last name of sampler or witnessed by | Hall |
Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 6466327821 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Bristol Machine | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L134-220-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 190840 | Nut Mfg. Lot Number(s) | 32307-190840 |
Washer Mfg. Lot Number(s) | N/A | Bolt Specification | N/A |
Bolt Length(s) | N/A | Nut Specification | ASTM A563 Gr. DH |
Washer Specification | N/A | Finish | HDG |
Diameter/Size | 1 1/4" | Bolt Mfg. Lot Number | N/A |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2020-09-23-15
DIME Test ID: 2020-09-23-15-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-09-30
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 09/29/2020
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | 32307-190840 | 150209 | Nut Proof Load | spaine |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 9/30/2020 ✔