Summary for Test 2020-08-12-21-2

Test performed: AASHTO T51-13

Project Information

Project IdentifiersProject ID: 214801
DEA: 031G6504
EFIS: 0319000105
DIST-CO-RTE-PM03-PLA,NEV-89-21.5/21.6,0.0/0.5
Award Date05/07/2020
Closeout Date03/16/2021
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACE HMA (TYPE A).
Location DescriptionPLACER AND NEVADA COUNTIES IN AND NEAR TRUCKEE FROM WEST RIVER STREET TO 0.2 MILE NORTH OF DEERFIELD DRIVE
QA Service Level1 (Verified on 03/24/2020)

Sample Information

Sample Taken Date08/12/2020 Sample Unique Key21
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/01/2020
Sample typeAcceptance A brief description of the sample AB PG 64-28 #1 test, #2(766410), #3(766411), #4(766412) No Test
The quantity of what the sample constitutes1 Can From where was the sample collectedSource
First name of sampler or witnessed bytiechert Last name of sampler or witnessed bymortis
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namewestern marathon Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-28
ModifiedNo Lot number
Sublot number Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-08-12-21
DIME Test ID: 2020-08-12-21-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2020-09-28

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 09/24/2020
Ductility of test #1 (D1): 75 cm
Ductility of sample: 75 cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/28/2020