Summary for Test 2020-09-21-29-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 214591 DEA: 051M2704 EFIS: 0519000089 |
---|---|
DIST-CO-RTE-PM | 05-SB-150-0.0/2.2 |
Award Date | 02/14/2020 |
Closeout Date | 08/23/2021 |
Work Description | RHMA OVERLAY, FULL WIDTH SEGMENT CORRECTION AND COLD PLANE AC. |
Location Description | SANTA BARBARA COUNTY IN AND NEAR CARPINTERIA FROM ROUTE 101/150 SEPARATION TO VENTURA COUNTY LINE |
QA Service Level | 1 (Verified on 05/29/2020) |
Sample Information
Sample Taken Date | 09/21/2020 | Sample Unique Key | 29 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/22/2020 |
Sample type | Verification | A brief description of the sample | Boxes of RHMA-G |
The quantity of what the sample constitutes | One JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Mark | Last name of sampler or witnessed by | Bennett |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Saticoy | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-09-21-29
DIME Test ID: 2020-09-21-29-1
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-09-25
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: E. Atkins
Date of test: 09/24/2020
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1726.8 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1587.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.28 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 7.77 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/25/2020 ✔