Summary for Test 2020-06-11-59-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 213887
DEA: 024H2604
EFIS: 0218000100
DIST-CO-RTE-PM02-SIS-97-R11.5/17.1
Award Date03/15/2019
Closeout Date01/04/2021
Work DescriptionCOLD PLANE AC, REPLACE AC SURFACING, PLACE AC, RUMBLE STRIP & STRIPE.
Location DescriptionSISKIYOU COUNTY ABOUT 12 MILES NORTH OF WEED FROM YELLOW BUTTE ROAD TO 0.6 MILE NORTH OF DEER MOUNTAIN ROAD
QA Service Level1 (Verified on 04/03/2019)

Sample Information

Sample Taken Date06/11/2020 Sample Unique Key59
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/11/2020
Sample typeVerification A brief description of the sampleCombined RAP (1/2-inch)
The quantity of what the sample constitutesJMF From where was the sample collectedManufacturer
First name of sampler or witnessed byAshton Last name of sampler or witnessed byErickson
Title of samplerRMC QC Telephone number of sampler
Laboratory sample identificationD78474B Linked DIME Sample ID
The fabricator/manufacturer/facility nameTruax Plant Transportation Laboratory (TL) Number990769
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceTruax Quarry
Aggregate Size1/2-inch Aggregate Source
RAP Stockpile Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix NumberNot set

Test Details

DIME Sample ID: 2020-06-11-59
DIME Test ID: 2020-06-11-59-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-09-17

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Ward Jenkins
Date of test: 06/13/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1581.4 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 5.83 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/17/2020