Summary for Test 2020-07-19-8-2

Test performed: AASHTO T51-13

Project Information

Project IdentifiersProject ID: 214628
DEA: 031G6604
EFIS: 0319000116
DIST-CO-RTE-PM03-BUT-162-12.6/15.6
Award Date03/17/2020
Closeout Date07/09/2021
Work DescriptionCOLD IN-PLACE RECYCLING, RHMA-G OVERLAY, AND COLD PLANE AC PAVEMENT.
Location DescriptionBUTTE COUNTY IN AND NEAR OROVILLE FROM 0.8 MILE EAST OF WILBUR ROAD TO FEATHER RIVER BRIDGE
QA Service Level1 (Verified on 03/24/2020)

Sample Information

Sample Taken Date07/19/2020 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/28/2020
Sample typeAcceptance A brief description of the sampleAsphalt Binder
The quantity of what the sample constitutes2 cans, #7 TEST (723260) From where was the sample collectedSource
First name of sampler or witnessed byAragon Last name of sampler or witnessed byAragon
Title of samplerQC Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUnknown Transportation Laboratory (TL) Number723260
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-10
ModifiedNo Lot number
Sublot number Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-07-19-8
DIME Test ID: 2020-07-19-8-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2020-09-15

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Ruben Macias
Date of test: 09/10/2020
Ductility of test #1 (D1): 103 cm
Ductility of sample: 103 cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/15/2020