Summary for Test 2015-01-16-7-3

Test performed: CTM 211-May 2010

Project Information

Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Award Date11/29/2012
Closeout Date07/31/2023
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 10/08/2012)

Sample Information

Sample Taken Date01/16/2015 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/16/2015
Sample typeAnnual Source Testing A brief description of the sampleOne inch PCC Aggregates
The quantity of what the sample constitutes8 Bags From where was the sample collectedSource
First name of sampler or witnessed byJeff Last name of sampler or witnessed byPollard
Title of samplerSupervisor of Technical Services Telephone number of samplerUnknown
Laboratory sample identification5110B Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameVulcan Sun Valley Boulevard Transportation Laboratory (TL) NumberC15 33
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0019::BOULEVARD
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpiles
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2015-01-16-7
DIME Test ID: 2015-01-16-7-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 211-May 2010: Abrasion of Coarse Aggregate by Use of the Los Angeles Abrasion Testing Machine
Test Release Date: 2015-02-23

Test Results


How many revolutions are required?: 500 Revolution Test
Input Type: Calculated
Tester's full name: Danilo Ferrer
Date of test: 01/23/2015
Grading: B
Percent wear: 34 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/23/2015