Summary for Test 2020-08-11-10-1

Test performed: AASHTO T240-17

Project Information

Project IdentifiersProject ID: 214907
DEA: 101K4204
EFIS: 1019000103
DIST-CO-RTE-PM10-MER,STA-165-30.6/36.7,0.0/1.6
Award Date06/09/2020
Closeout Date04/14/2021
Work DescriptionCOLD PLANE AC PAVEMENT, RESURFACE WITH RHMA, AND MICRO-SURFACING.
Location DescriptionMERCED COUNTY IN AND NEAR HILMAR FROM MERCED RIVER BRIDGE TO STANISLAUS COUNTY LINE AND IN STANISLAUS COUNTY NEAR TURLOCK FROM MERCED COUNTY LINE TO ROUTE 99/165 SEPARATION
QA Service Level1 (Verified on 04/28/2020)

Sample Information

Sample Taken Date08/11/2020 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/14/2020
Sample typeDepartment Acceptance A brief description of the samplePG 64-10 Asphalt Binder #1 Test, #2(034009),#3(034012), #4(034018), #5(772133),#6(772135), #7(708567), #8(994277) No Test
The quantity of what the sample constitutes1 can From where was the sample collectedSource
First name of sampler or witnessed byM Last name of sampler or witnessed byCozad
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameValero - Benicia, CA Transportation Laboratory (TL) Number034007
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-10
ModifiedNo Lot number1
Sublot number1 Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-08-11-10
DIME Test ID: 2020-08-11-10-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2020-09-25

Test Results


Is mass change based on one or two containers?: One
Input Type: Measured
Tester's full name: Ruben Macias
Date of test: 09/10/2020
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 167.800 grams
Mass of container #1 before test (m1i): 202.867 grams
Mass of container #1 after test (m1f): 200.967 grams
Average mass change: -5.418 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/25/2020