Summary for Test 2020-06-08-47-2

Test performed: AASHTO T51-13

Project Information

Project IdentifiersProject ID: 214589
DEA: 020J1604
DIST-CO-RTE-PM02-PLU-284-0.0/8.3
Award Date02/11/2020
Closeout Date10/06/2020
Work DescriptionPLACE HMA (TYPE A), PRECOATED AGGREGATE (SEAL COAT), HMA (LEVELING).
Location DescriptionPLUMAS COUNTY NEAR CHILCOOT FROM ROUTE 70 TO 1 MILE NORTH OF LITTLE LAST CHANCE CREEK BRIDGE NUMBER 09-0072
QA Service Level1 (Verified on 01/22/2020)

Sample Information

Sample Taken Date06/08/2020 Sample Unique Key47
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/28/2020
Sample typeAcceptance A brief description of the sampleAB PG58-22
The quantity of what the sample constitutes2 Cans, #1 TEST (2 Months) From where was the sample collectedSource
First name of sampler or witnessed byCGI Last name of sampler or witnessed byCGI
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMarathon Transportation Laboratory (TL) Number896981
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number0
Sublot number0 Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-06-08-47
DIME Test ID: 2020-06-08-47-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2020-09-23

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Ruben Macias
Date of test: 09/03/2020
Ductility of test #1 (D1): 100 cm
Ductility of sample: 100 cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/23/2020