Summary for Test 2020-08-19-23-4

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 214756
DEA: 050N7AU4
EFIS: 0520000030
DIST-CO-RTE-PM05-SB-101-1.4/4.8
Award DateNot set
Closeout Date09/27/2022
Work DescriptionSegment 4A - Carpinteria: Construct HOV lanes and rehabilitation. Source inspection of sign structure trusses, lighting structures, epoxy coated rebar, precast box culverts, precast RCP.
Location DescriptionCARPINTERIA FROM 0.2 MILE SOUTH OF BAILARD AVENUE OVERCROSSING TO 0.7 MILE SOUTH OF SOUTH PADARO LANE
QA Service Level1 (Verified on 03/09/2020)

Sample Information

Sample Taken Date08/19/2020 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/21/2020
Sample typeVerification A brief description of the sampleBags of Untreated Aggregate
The quantity of what the sample constitutesOne JMF Verificatioin From where was the sample collectedManufacturer
First name of sampler or witnessed byD Last name of sampler or witnessed byLaChaine
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Santa Paula Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0046::BIG ROCK CREEK- GRANITE
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedAt the Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-08-19-23
DIME Test ID: 2020-08-19-23-4
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2020-09-02

Test Results


How many times will the test be run?: 3 Times
Input Type: Calculated
Tester's full name: Daniel Gingras
Date of test: 09/01/2020
Sand Equivalent (Test 1): 74
Sand Equivalent (Test 2): 75
Sand Equivalent (Test 3): 76
Sand Equivalent: 75
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/2/2020