Summary for Test 2015-01-20-5-3
Test performed: CTM 229-June 2011Project Information
Project Identifiers | Project ID: 3958 DEA: 07215914 EFIS: 0700001831 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-1.2/2.1 |
Award Date | 12/31/1969 |
Closeout Date | 06/14/2016 |
Work Description | WIDEN AND REALIGN FREEWAY AND RECONSTRUCT OVERCROSSING STRUCTURE. |
Location Description | LOS ANGELES COUNTY IN SANTA FE SPRINGS FROM 0.3 MILE SOUTH OF NORTH FORK COYOTE CREEK BRIDGE TO 0.3 MILE NORTH OF MARQUARDT AVENUE AND AT NORWALK HUB AND LOS ANGELES REGIONAL TRANSPORTATION MANAGEMENT CENTER |
QA Service Level | 1 (Verified on 05/01/2012) |
Sample Information
Sample Taken Date | 01/20/2015 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/21/2015 |
Sample type | Acceptance | A brief description of the sample | Class 3 Aggregate Base |
The quantity of what the sample constitutes | 2 bags | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Jose | Last name of sampler or witnessed by | Burbano |
Title of sampler | Assistant RE | Telephone number of sampler | Unknown |
Laboratory sample identification | 5014B | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Windrows placed on route 5 SB section Sta 89 50 | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Unknown |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Windrows placed on route 5 SB section Sta 89 50 |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2015-01-20-5
DIME Test ID: 2015-01-20-5-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 229-June 2011: Method of Test for Durability Index
Test Release Date: 2015-02-23
Test Results
What test(s) are being run?: Coarse durability and fine durability
Input Type: Calculated
Tester's full name: Vincent Onoh
Date of test: 01/26/2015
Coarse durability index: 68
Fine durability index: 43
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/23/2015 ✔