Summary for Test 2020-08-10-28-2
Test performed: ASTM D36-14ε1Project Information
Project Identifiers | Project ID: 214797 DEA: 031G2504 EFIS: 0318000107 |
---|---|
DIST-CO-RTE-PM | 03-ED-193-19.3/R24.7 |
Award Date | 05/19/2020 |
Closeout Date | 03/16/2021 |
Work Description | COLD PLANE AC PAVEMENT, RHMA-G OVERLAY, & REPLACE GUARDRAIL. |
Location Description | EL DORADO COUNTY NEAR PLACERVILLE FROM 0.1 MILE NORTH OF GARDEN VALLEY ROAD TO SOUTH FORK AMERICAN RIVER BRIDGE |
QA Service Level | 1 (Verified on 03/24/2020) |
Sample Information
Sample Taken Date | 08/10/2020 | Sample Unique Key | 28 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/14/2020 |
Sample type | Acceptance | A brief description of the sample | #1 test PG 64-16 |
The quantity of what the sample constitutes | 1 Can | From where was the sample collected | Source |
First name of sampler or witnessed by | Nikku | Last name of sampler or witnessed by | Lopez |
Title of sampler | TESTER | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | George Reed Plant | Transportation Laboratory (TL) Number | 788465 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
---|---|---|---|
Performance Grade | PG 64-16 | Lot number | |
Sublot number | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2020-08-10-28
DIME Test ID: 2020-08-10-28-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2020-08-26
Test Results
ASTM Thermometer used?: C
Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 08/26/2020
Softening Point Sample 1: 73 C
Softening Point Sample 2: 73 C
Bath Liquid: freshly boiled distilled water
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/26/2020 ✔