Summary for Test 2020-06-08-46-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 214589 DEA: 020J1604 |
---|---|
DIST-CO-RTE-PM | 02-PLU-284-0.0/8.3 |
Award Date | 02/11/2020 |
Closeout Date | 10/06/2020 |
Work Description | PLACE HMA (TYPE A), PRECOATED AGGREGATE (SEAL COAT), HMA (LEVELING). |
Location Description | PLUMAS COUNTY NEAR CHILCOOT FROM ROUTE 70 TO 1 MILE NORTH OF LITTLE LAST CHANCE CREEK BRIDGE NUMBER 09-0072 |
QA Service Level | 1 (Verified on 01/22/2020) |
Sample Information
Sample Taken Date | 06/08/2020 | Sample Unique Key | 46 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/09/2020 |
Sample type | Verification | A brief description of the sample | 3/4-inch Type A HMA (eq. PG 64-16) 23.0 RAP, 1.0 Lime |
The quantity of what the sample constitutes | JMF Verification and PSE | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | CGI | Last name of sampler or witnessed by | CGI |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D78459 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Ward Lake Plant, Litchfield, CA | Transportation Laboratory (TL) Number | 733200 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-06-08-46
DIME Test ID: 2020-06-08-46-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-08-27
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Ward Jenkins
Date of test: 06/26/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2,103.9 g
Mass Loss: 0.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.64 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 5.51 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/27/2020 ✔