Summary for Test 2020-08-10-8-4

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 77777
DEA: CHEM-STOCK
EFIS: CHEM-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date08/10/2020 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/19/2020
Sample typeQuality Assurance A brief description of the sampleHigh Strength Fastener Assemblies
The quantity of what the sample constitutes300 bolts and nuts, 600 washers From where was the sample collectedFabricator
First name of sampler or witnessed byCraig Last name of sampler or witnessed byHager
Title of samplerQA Inspector Telephone number of sampler925-899-1184
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUIS Lindon UT Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB29-044-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0130566
Heat Number(s)bolt 75061539 nut 75078681 washer 31542750 Nut Mfg. Lot Number(s)32504-75078681
Washer Mfg. Lot Number(s)D2166 Bolt SpecificationA325
Bolt Length(s)5-1/2" Nut SpecificationA563-DH
Washer SpecificationF436 FinishMG
Diameter/Size1-1/2" Bolt Mfg. Lot NumberM4405
Rocap Test Requirement(s)Yes Lubricant Requirements(s)None

Test Details

DIME Sample ID: 2020-08-10-8
DIME Test ID: 2020-08-10-8-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-08-24

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/19/2020
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
13B32504-75078681217397Nut Prooffsaylor

General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 8/24/2020