Summary for Test 2020-07-31-14-5

Test performed: CTM 206-October 2011

Project Information

Project IdentifiersProject ID: 214901
DEA: 044Q3304
EFIS: 0419000378
DIST-CO-RTE-PM04-CC-24-R0.4/1.0
Award Date06/12/2020
Closeout Date04/12/2021
Work DescriptionCOLD PLANE PAVEMENT AND OVERLAY WITH RUBBERIZED HOT MIX ASPHALT.
Location DescriptionCONTRA COSTA COUNTY FROM FISH RANCH ROAD TO 0.2 MILE WEST OF GATEWAY BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 10/19/2020)

Sample Information

Sample Taken Date07/31/2020 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing12/31/2019
Sample typeVerification A brief description of the sampleMix Aggregates to use in 1/2" RHMA-O-WMA
The quantity of what the sample constitutes18 Bags (Shipped in 3 group of 6) From where was the sample collectedFabricator
First name of sampler or witnessed byLisa Last name of sampler or witnessed byNordine
Title of samplerQC Lab Tech Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameDSG Sunol Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0007
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedSample collected from DSG Sonul
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-07-31-14
DIME Test ID: 2020-07-31-14-5
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: CTM 206-October 2011: Method of Test for Specific Gravity and Absorption of Coarse Aggregate
Test Release Date: 2020-08-19

Test Results


How will the aggregate be used?: hot mix asphalt
Input Type: Measured
Tester's full name: Nicholas Shelly
Date of test: 08/05/2020
Mass of Sample + Container (in water): 3143.3 grams
Mass of Container (in water): 0 grams
Mass of Saturated Surface Dry Sample: 5032.8 grams
Mass of Oven Dry Sample: 4946.8 grams
Mass of Sample (in water): 3143.3 grams
Mass of Water Absorbed: 86 grams
% Water Absorbed: 1.7 %
Bulk Oven Dried Specific Gravity: 2.62
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/19/2020