Summary for Test 2020-07-01-5-3

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 214756
DEA: 050N7AU4
EFIS: 0520000030
DIST-CO-RTE-PM05-SB-101-1.4/4.8
Award DateNot set
Closeout Date09/27/2022
Work DescriptionSegment 4A - Carpinteria: Construct HOV lanes and rehabilitation. Source inspection of sign structure trusses, lighting structures, epoxy coated rebar, precast box culverts, precast RCP.
Location DescriptionCARPINTERIA FROM 0.2 MILE SOUTH OF BAILARD AVENUE OVERCROSSING TO 0.7 MILE SOUTH OF SOUTH PADARO LANE
QA Service Level1 (Verified on 03/09/2020)

Sample Information

Sample Taken Date07/01/2020 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/02/2020
Sample typeQuality Control A brief description of the sampleConcrete Test Samples
The quantity of what the sample constitutes8 6X12 CYLINDERS From where was the sample collectedFabricator
First name of sampler or witnessed byJoe Last name of sampler or witnessed byBuckley
Title of samplerQC Manager Telephone number of sampler916-716-3405
Laboratory sample identification7-1 box Linked DIME Sample IDna
The fabricator/manufacturer/facility nameForterra Pipe and Precast, Florin Rd Transportation Laboratory (TL) Numberna
Inspector Lot Number from the Transportation Laboratory (TL) Formna Structure unique identifier36-0000
Structure nameHighway 132

Material Information

Material TypeConcrete The concrete mix design number5H
The truck number from where the sample was collectedNA The batch plant ticket number from where the sample was collected141651
Concrete batch plantForterra Florin Rd The fabricator/manufacturer designation for the samplebatch
A detailed description of where the material sample was collectedconveyor belt Where the material sample would have been placed if not sampledRCBC
From Lot No.NA Bag Lot No.NA

Test Details

DIME Sample ID: 2020-07-01-5
DIME Test ID: 2020-07-01-5-3
Testing Lab: Rinker Materials
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2020-08-08

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Joe Buckley
Date of test: 07/29/2020
Capped in accordance with?: ASTM C1231
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 194650 lb
Maximum load on cylinder 2: 186770 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Age of specimen in hours: 672 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 6750 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/8/2020